Permit Number: TC-RES-1222-01678
Parcel: 138191990

Address:
6635 S 10TH AV

Review Status: Requires Resubmit

Review Details: RESIDENTIAL NEW DWELLING v.1

Permit Number - TC-RES-1222-01678
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
01/12/2023 Site Zoning APPROVED
01/10/2023 Site Engineering NOT REQUIRED
01/03/2023 Site Landscape NOT REQUIRED
01/30/2023 Bldg Permits - Post Review Express PENDING ASSIGNMENT
01/30/2023 Residential Building REQUIRES RESUBMIT 1. TEP usually requires the service panel on the property at the closest building to the service transformer. The overhead service conductor over the proposed building requires an 8’ clearance above the roof, E3604.2.1. The necessary mast height at the existing panel location may not be a feasible installation. Update the plans with a relocated service panel and feeder to dwelling or show an overhead line with appropriate clearance over the garage.
12/30/2022 PDSD Application Completeness Express REVIEW COMPLETED