Permit: TC-RES-1222-01678
Permit Details
Status:
Inspections Complete
Type:
Residential Building - One or Two Family
Address:
6635 S 10TH AV
Address NEW:
6635 S 10TH AV
Apply Date:
12/21/2022
Applicant:
vance goodman
Description:
RAMADA AND GARAGE ADDITION
Permit Reviews
Permit Number - TC-RES-1222-01678
Permit Status: Inspections complete
Permit Description: RAMADA AND GARAGE ADDITION
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 12/30/2022 | RESIDENTIAL NEW DWELLING v.1 | 01/30/2023 | REQUIRES RESUBMIT |
| 03/02/2023 | RESIDENTIAL NEW DWELLING v.2 | 03/03/2023 | APPROVED |
Outstanding Activity Conditions
Permit Number - TC-RES-1222-01678
Permit Status: Inspections complete
Permit Description: RAMADA AND GARAGE ADDITION
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 01/30/2023 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. |
Conditions
Permit Number - TC-RES-1222-01678
Permit Status: Inspections complete
Permit Description: RAMADA AND GARAGE ADDITION
| Date | Description | Comments |
|---|---|---|
| 03/03/2023 | Contractor with active Arizona Contractor's License for specified scope of work required prior to issuance of permit. |
Outstanding Inspections
Permit Status: Inspections Complete
Permit Number: TC-RES-1222-01678
Permite Description: RAMADA AND GARAGE ADDITION
Total Outstanding Inspections - 1
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/30/2023 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | N/A | Re-inspection required | plans show a 60 amp sub panel installed but home runs were put in to main panel, please revise drawings or install sub panel, ok to stucco but do not drywall |
Completed Inspections
Permit Status: Inspections Complete
Permit Number: TC-RES-1222-01678
Permit Description: RAMADA AND GARAGE ADDITION
Total Completed Inspections - 11
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/21/2023 | COT - RSBU - Preslab | Passed | Approved rebar per plans. Okay for concrete placement in footings and slab. 4/21/2023 | |
| 04/21/2023 | COT - RSEL - Grounding/Bonding | Passed | ||
| 04/21/2023 | COT - RSBU - Excavation/Rebar/Zoning | Passed | Approved rebar per plans. Okay for concrete placement in footings and slab. 4/21/2023 | |
| 04/28/2023 | COT - RSEL - Electrical Underground | Passed | Okay to back fill. 4/28/2023 | |
| 06/27/2023 | COT - RSBU - Roof Nailing | Passed | ||
| 06/27/2023 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | ||
| 07/12/2023 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | ||
| 07/14/2023 | RSBU - Building Final | Passed | ||
| 07/14/2023 | COT - RSEL - Electrical Final | Passed | ||
| 07/14/2023 | COT - RSBU - Interior Shear Bracing | Passed | ||
| 07/14/2023 | COT - RSEL - Outdoor Lighting | Passed |