Review Status: In Review
Review Details: RESIDENTIAL ADD/ALT v.1
Permit Number - TC-RES-1125-05568
Review Name: RESIDENTIAL ADD/ALT v.1
Review Status: In Review
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 12/09/2025 | Residential Building - Standard | APPROVED | |||
| 12/04/2025 | Site Engineering - Standard | NOT REQUIRED | |||
| N/A | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| N/A | Site Landscape - Standard | PENDING ASSIGNMENT | |||
| 12/03/2025 | Residential Zoning | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Claire Leighou, Planner PROJECT: TC-RES-1125-05568 12791 E TORTOISE POINTE DR Ramada (1st Review) TRANSMITTAL DATE: 12/3/25 Please resubmit revised drawings with a detailed response letter stating how all Zoning Review Section comments were addressed. This site is located in the R-1 zone (UDC 4.7.8). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5 -.9. Comment: The minimum required setback from the side and rear property lines for new structures in the R-1 zone is the greater of 6’ or 2/3 the wall height of the adjacent structure, per UDC table 6.3-2.A. The first option to make the proposed ramada compliant is to place it 4” further south, for a total distance of 6’ from the north property line. The second option is a neighbor waiver. Per UDC Article 6.6.2.D, an accessory structure that is detached from a principal structure shall comply with the setback standards of the principal structure, except that the accessory structure may be built to a parcel line with the consent of the adjacent property owner(s). To secure this neighbor setback waiver the following statement must be provided on the plot plan and be signed and dated by the adjacent property owner(s) (12804 E Tortoise Pointe Pl). My name is____________________ and I am the owner of the property located at_______________________. I have reviewed the site plan and I have no objection to structure being located or constructed________ feet from the property line as depicted on the site plan. Signature: _______________________Date: ___________________________ The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code If you have any questions about this transmittal, please contact Claire Leighou at claire.leighou@tucsonaz.gov. Thank you! |
||
| 11/21/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |