Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: TC-RES-1124-06414
Parcel: 133132250

Address:
1215 N TRACY AV

Review Status: Requires Resubmit

Review Details: RESIDENTIAL NEW DWELLING v.1

Permit Number - TC-RES-1124-06414
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
12/06/2024 Site Engineering NOT REQUIRED
11/12/2024 Site Landscape NOT REQUIRED
12/16/2024 Bldg Permits - Post Review PENDING ASSIGNMENT
11/26/2024 Residential Building REQUIRES RESUBMIT Roof projections extending into the 3-foot fire separation distance to the adjoining (neighboring) property line require not less than one-hour fire-resistive construction on the underside, R302.1 (City of Tucson Amended). Or remove the roof structure from the 3 foot fire separation distance.
12/16/2024 Site Zoning REQUIRES RESUBMIT PDSD TRANSMITTAL

FROM: Bobby Parsons
Zoning Section Review

PROJECT: TC-RES-1124-06414
1215 N Tracy Ave Tucson, AZ 85715
Porch Addition (1st review)

TRANSMITTAL DATE: 12/16/2024

This site is located in the R-2 zone (UDC 4.7.9). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.6, .9, & .10.

Comments: Please resubmit revised drawings along with a detailed response letter which states how all Zoning Review Section comments were addressed.

1. Comment: The site plan should be designed to include the information as noted on the sample site plan. Please see https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/residential_plot_plan_requirements.pdf for reference.
2. Comment: Per UDC 6.4.3.C.1, “Roofed areas, open on at least one side, which provide shelter to exterior areas such as balconies, entrances, stoops, and terraces, provided they are not used for utilities, maintenance, laundry, storage, or motor vehicle parking are excluded from lot coverage calculations.” Please remove the porches from your lot coverage calculations and update the calculations.
3. Comment: Please draw label and dimension the half right of way from the centerline of N. Tracy Ave to the face of curb and from the face of curb to the property line. Please refer to Bk30 Pg 51 of City of Tucson Maps and Records if needed. https://maps-and-records.tucsonaz.gov/subdivisions/details/3522.
4. Comment: Site zoning is unable to approve the building permit until the Design Development Option (DDO) has been approved. Please see below.

5. Comment: The following comments are related to an application for a Design Development Option (DDO) (UDC 3.11.1):

The minimum setback for the R-2 zone is the greater of 6’ or 2/3 (Height) of the structure’s wall facing each interior property line (Table 6.3-2.A). Based on a proposed wall height of 8’-7”, the minimum required setback to the South property line is 6’. The proposed setback for the porch along the South property line is 2’-2”. The proposed setback will require approval through the DDO application process. Please contact Mark Castro at Mark.Castro@tucsonaz.gov or Georgia.Pennington@tucsonaz.gov if needed. https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/planning-amp-zoning/ddo_for_setback_and_height_udc.pdf.

If you have any questions about this transmittal, please contact Bobby Parsons at Robert.Parsons@tucsonaz.gov.
11/05/2024 PDSD Application Completeness REVIEW COMPLETED