Permit: TC-RES-1124-06414
Permit Details
Status:
Inspections
Type:
Residential Building - One or Two Family
Address:
1215 N TRACY AV
Address NEW:
1215 N TRACY AV
Apply Date:
11/05/2024
Applicant:
alex enoch
Description:
Porch Addition
Permit Reviews
Permit Number - TC-RES-1124-06414
Permit Status: Inspections
Permit Description: Porch Addition
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 02/07/2025 | RESIDENTIAL NEW DWELLING v.2 | 02/12/2025 | APPROVED |
| 11/05/2024 | RESIDENTIAL NEW DWELLING v.1 | 12/16/2024 | REQUIRES RESUBMIT |
Conditions
Permit Number - TC-RES-1124-06414
Permit Status: Inspections
Permit Description: Porch Addition
| Date | Description | Comments |
|---|---|---|
| 02/07/2025 | Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/pdsd_owner_builder_affidavit_081623.pdf, is required prior to issuance of permit. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit. |
Outstanding Inspections
Permit Status: Inspections
Permit Number: TC-RES-1124-06414
Permite Description: Porch Addition
Total Outstanding Inspections - 5
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/17/2025 | COT - RSBU - Excavation/Rebar/Zoning | N/A | Not Ready | Concrete has been placed; provide letter from licensed contractor on letterhead stating that work was performed plans. |
| 04/17/2025 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | N/A | Not Applicable | |
| 04/17/2025 | COT - RSBU - Roof Nailing | N/A | Not Ready | Roof deck is covered; work that IS exposed does not match approved plans. |
| 04/17/2025 | COT - RSBU - Preslab | N/A | Not Ready | concrete has been placed |
| 04/17/2025 | RSBU - Building Progress | N/A | Re-inspection required | 1-New rafters are connected to existing fascia; plans show fascia removed and rafters on bearing wall. 2-Joist hangers and hurricane clips have been installed with screws; verify capacity is acceptable per manufacturer. 3-Rafters and beams do not match plans. |
Completed Inspections
Permit Status: Inspections
Permit Number: TC-RES-1124-06414
Permit Description: Porch Addition
Total Completed Inspections - 1
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/21/2025 | RSBU - Building Final | Passed |