Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL SOLAR v.1
Permit Number - TC-RES-1122-00461
Review Name: RESIDENTIAL SOLAR v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/25/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 01/25/2023 | Light Residential Building Review (OIP) | REQUIRES RESUBMIT | TC-RES-1122-00461: Structural: Clarify connection to structure of building. S 1.0 shows 1" screws into metal roof only. Provide up-lift calculations. Show a plan of sufficient lag-bolt connections for maintaining the up-lift calculation and with standoff placement for preventing point loads over 45 pounds, R301.1. |
||
| 01/05/2023 | PDSD Application Completeness Express | REVIEW COMPLETED |