Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: In Review
Review Details: RESIDENTIAL NEW DWELLING v.1
Permit Number - TC-RES-1024-06170
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: In Review
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
10/25/2024 | Site Landscape | NOT REQUIRED | |||
N/A | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
N/A | Site Engineering | PENDING ASSIGNMENT | |||
N/A | Site Zoning | PENDING ASSIGNMENT | |||
11/13/2024 | Residential Building | REQUIRES RESUBMIT | Permit Review TC-RES-1024-06170 (833 N 4TH AV TUCSON, AZ 85705) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2018 International Residential Code (IRC), 2017 National Electrical Code (NEC). General: 1. This structure does not appear to be a permitted dwelling. Historic records show this structure as a storage building. 2. Provide permit documents showing the conversion of this structure from storage to a dwelling living space. 3. Demonstrate compliance with NEC 230.2 (Number of Services). A second metered electrical service is not permitted for this structure without showing it is a permitted dwelling unit. An ADU or 2nd dwelling is an independently functioning dwelling and requires compliance with the 2018 IRC and City of Tucson building ordinances. A dwelling unit (includes a kitchen) requires collection of development impact fee when the building permit is processed, City of Tucson Ordinance #11203. 4. Each dwelling unit building requires a separate Pima County assigned street address and unit number, R319. Notate each dwelling address and unit number on the site plan. 5. If there is not permit history of converting this structure from a storage building to a dwelling, you will need to withdraw this permit and apply for a Residential New Dwelling permit and provide a complete set of construction plans showing compliance with the adopted codes and ordinances. Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov |
||
10/23/2024 | PDSD Application Completeness | REVIEW COMPLETED |