12/07/2023 Residential Building APPROVED Approved with comments added on the plans: Provide a Grounding Electrode System at the detached solar support structure per NEC 690.47.
12/12/2023 Bldg Permits - Post Review Express PENDING ASSIGNMENT
12/12/2023 Site Zoning REQUIRES RESUBMIT PDSD TRANSMITTAL
FROM: PDSD Zoning Review
PROJECT: TC-RES-0923-07801
6051 E 26th St – R-1
Shade Structure w/Solar
TRANSMITTAL DATE: 12/12/2023


Provided a detailed comment response letter with your submittal that clearly shows how you have addressed all comments with your next submittal.

1. COMMENT: Provide the height of the proposed structure, UDC 6.4.4.A. Building height is the vertical distance measured from the design grade elevation to the highest point of a flat roof; to the deck line of a mansard roof; or to the middle (between the eave and ridge ) of the highest gable of a pitched or hipped roof, except as follows: (See Figure 6.4.4-A, Measurement of Building Height .)

This comment is still applicable ensure that the neighbor waiver is put on the site plan.
2. COMMENT: Setbacks in the R-1 zone are 6’ or 2/3 * Height of the structure (whichever is greater) the proposed setback for the structure from the property line is 2’ 11”. A neighbor waiver signed by the homeowner located to the north of the property (adjacent to the structure) will be required. Provide this signed statement on the site plan on the next submittal.

“My Name is ______________ and I am the owner of the property located at ____________. I have reviewed the site plan and I have no objections to structure being located or constructed ______ feet from the property line as depicted on the site plan

Signature:__________________”


If you have any questions about this transmittal, Contact Paul Camarena at (520)837-4986 or by email Paul.Camarena@tucsonaz.gov
11/28/2023 PDSD Application Completeness Express REVIEW COMPLETED