Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.1
Permit Number - TC-RES-0923-07801
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/11/2023 | Site Engineering | NOT REQUIRED | |||
| 09/26/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 09/21/2023 | Residential Building | REQUIRES RESUBMIT | Permit Review TC-RES-0923-07801 (6051 E 26TH ST TUCSON, AZ 85711) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2018 International Residential Code (IRC). 1. The Engineer of Record (EOR) shall seal the relevant structural pages of the design plans. Each of the 30x20x9’2 sheets 1-3, and Sheets S-01 – S-02. Arizona Revised Statutes 32-125, Board of Technical Registration Rules R4-30-304, R106.1. 2. Welding requires a Special Inspection. EOR shall note this requirement on 30x20x9’2 sheet3. See ‘general structural notes’ #5. 3. Provide a Special Inspection form, https://www.tucsonaz.gov/files/sharedassets/public/v/1/city-services/planning-development-services/documents/special_inspection_certificate.pdf. Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov |
||
| 09/26/2023 | Site Zoning | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: PDSD Zoning Review PROJECT: TC-RES-0923-07801 6051 E 26th St – R-1 Shade Structure w/Solar TRANSMITTAL DATE: 09/26/2023 Provided a detailed comment response letter with your submittal that clearly shows how you have addressed all comments with your next submittal. 1. COMMENT: If pergola is used to attach the exiting structure to the structure to the rear then the scope of work needs to be updated on the next submittal to show that the pergola addition is a part of this permit. Pergola must be solid, 5’ wide, and support a 20-pound live load. 2. COMMENT: Setbacks in the R-1 zone are 6’ or 2/3 * Height of the structure (whichever is greater) the proposed setback for the structure from the property line is 2’ 11”. A neighbor waiver signed by the homeowner located to the north of the property (adjacent to the structure) will be required. Provide this signed statement on the site plan on the next submittal. “My Name is ______________ and I am the owner of the property located at ____________. I have reviewed the site plan and I have no objections to structure being located or constructed ______ feet from the property line as depicted on the site plan Signature:__________________” 3.COMMENT: No documentation could be found for the detached structure located to the northeast of the property. Provide a setback dimension from the north and east property line adjacent to the detached structure. If the structure is not meeting setbacks listed above provide a neighbor waiver for this structure on the next submittal. Provide a height for the structure on the next submittal. If a neighbor waiver cannot be acquired, a Design Development Option will be required to reduce setbacks. Information on development packages can be found here: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Development-Package For questions regarding Zoning comments, please contact me at: Iman.Monshizadeh@tucsonaz.gov |
||
| 09/07/2023 | PDSD Application Completeness Express | REVIEW COMPLETED |