Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: TC-RES-0824-04848
Parcel: 11943001A

Review Status: Requires Resubmit

Review Details: RESIDENTIAL SIMPLE REVIEW v.2

Permit Number - TC-RES-0824-04848
Review Name: RESIDENTIAL SIMPLE REVIEW v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
08/28/2024 Bldg Permits - Post Review PENDING ASSIGNMENT
08/28/2024 Light Residential Building Review (OIP) REQUIRES RESUBMIT 1. Note and specify all piping materials and sizes, P2609.
2. Provide a complete gas piping template showing the connection and length from the meter to all attached appliances, G2401.1, R301.1: Include pipe size, type (Black Iron, Poly) and length. Provide appliance demands, G2413.4.1. Connection must be shown to all appliances.

Here are the Step-by-Step instructions on how to resubmit: https://www.tucsonaz.gov/files/sharedassets/public/pdsd/documents/tdc-faq/new-pdfs/revisions-and-resubmittals.pdf For questions: Building_Official@tucsonaz.gov
08/28/2024 PDSD Application Completeness REVIEW COMPLETED