Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.1
Permit Number - TC-RES-0823-07205
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/21/2023 | Site Engineering | NOT REQUIRED | |||
| 09/06/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 09/06/2023 | Residential Building | REQUIRES RESUBMIT | Permit Review TC-RES-0823-07205 (9242 E HELEN ST TUCSON, AZ 85715) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2018 International Residential Code (IRC). Plumbing Plans: 1. Show a two-way cleanout at the building exterior, one-way cleanout at 100’ intervals and at change of direction exceeding 45 degrees, P3005.2. Mechanical Plans: 1. Provide demand calculations in accordance with Manual J/S/D standards, M1401.3, M1601.1. Systems shall be sized in accordance with Manual S based on building loads calculated in accordance with Manual J and duct systems sized in accordance with Manual D. Notate the mechanical plans if system calculations will be provided by deferred submittal. Electrical Plans: 1. Show Combination ARC Fault protection for all circuits listed in E3902.16. All Arc Fault circuit interrupters shall be installed in readily accessible locations, E3902.15. Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov |
||
| 08/22/2023 | Site Zoning | REQUIRES RESUBMIT | FROM: Paul Camarena PDSD Zoning Review Section PROJECT: TC-RES-0823-07205 9242 E HELEN ST Zoning R-1 TRANSMITTAL DATE:August 22, 2023 COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed. 1.COMMENT: Provide permit documentation for the ramada, please provide the height and square footage and setback dimension. 2.COMMENT: Provide a setback dimension for the new addition from the property line to the proposed structure. The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure’s wall facing each interior property line (Table 6.3-2.A). 3.COMMENT: Provide a floor plan for the existing residence on the plan so that Zoning can verify if the requirements of UDC Article 4.9.7.B.7 are applicable to this project. If you have any questions about this transmittal, Contact Paul Camarena at (520)837-4986 or by email Paul.Camarena@tucsonaz.gov |
||
| 08/17/2023 | PDSD Application Completeness Express | REVIEW COMPLETED |