Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL ADD/ALT v.2
Permit Number - TC-RES-0726-04085
Review Name: RESIDENTIAL ADD/ALT v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/03/2026 | Design Review - Standard | NOT REQUIRED | Proposed carport on the south side (rear) of property will not be visible from Edison Street, so no NPZ review will be required. | ||
| 09/10/2026 | Residential Engineering | NOT REQUIRED | |||
| 09/10/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 09/01/2026 | Residential Building - Standard | REQUIRES RESUBMIT | Please provide a 1 hour fire rating for the west side of the proposed carport that is 2 feet from the property line. 1. The structure may not extend to a point closer than 3 feet from the neighboring property line without fire rated protection for fire spread. Provide compliance with R302.1 (City of Tucson Amended) by protecting the structure placed within 3 feet of the property line in compliance with IBC Table 721.1(2). Include a one hour rated wall below the roof edge with foundation along the full length of structure near the property line or relocate the structure out of the fire separation distance. |
||
| 09/02/2026 | Residential Zoning | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Erick Bieber Planning & Development Services Department – Zoning Review Section PROJECT: TC-RES-0726-04085 – Residential Building 1720 E Edison St, Tucson, AZ 85719 Residential Addition/Alteration (1st Review) TRANSMITTAL DATE: September 2nd, 2026 This site is located in the R-1 zone (UDC 4.7.8). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5 -.9 & .12. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Correct plans, as noted in the comments below, along with a response letter indicating how all Site Zoning comments were addressed. 1. (Comment) The neighbor setback waiver indicated on the site plan is not sufficient. Please provide a neighbor setback waiver that is signed and dated by the adjacent property owner at 1714 E Edison St. 2. (Comment) Please provide setback measurements from the proposed carport to all adjacent structures. 3. (Comment) This site is located in the Jefferson Park Neighborhood Preservation Zone. If it is determined that the carport is visible from the ROW, design review will be required. Zoning can not approve the permit until it is determined that the carport is not visible from the ROW, or until design review has been completed and approved. The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code For questions regarding Zoning comments, please contact me at: Erick.Bieber@tucsonaz.gov |
||
| 09/01/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |