Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-RES-0726-03783
Parcel: 119210030

Review Status: Requires Resubmit

Review Details: RESIDENTIAL SIMPLE REVIEW REVISION v.2

Permit Number - TC-RES-0726-03783
Review Name: RESIDENTIAL SIMPLE REVIEW REVISION v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
09/15/2026 Bldg Permits - Post Review Express PENDING ASSIGNMENT
09/15/2026 Light Residential Building Review (OIP) Express REQUIRES RESUBMIT If you have questions regarding this Review, please contact Juan Quintana at juan.quintana@tucsonaz.gov
Please resubmit addressing the following comments:
1) Please show measurements between ESS and between bollards to show it adheres to the measurements presented in R330.8.3.
2) SteelPost 4 Bollard by McCue is listed as 30" tall and base is within 8" length minimum. These dimensions do not adhere to the minimum 36" height requirement and 8" Steel Plate length of section R330.8.3.1.1.2 but shall be permissible if the steel pipe is filled with concrete. Please show that bollards will be filled with concrete per 330.8.3.1.1.3 or a new method of protection from vehicular impact.
3) Please show that the use of anchors will not damage structural components including but not limited to Post-Tension Tendons.
09/14/2026 PDSD Application Completeness Express REVIEW COMPLETED