Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL SIMPLE REVIEW v.2
Permit Number - TC-RES-0725-03602
Review Name: RESIDENTIAL SIMPLE REVIEW v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/28/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 07/28/2025 | Addressing Validation | REQUIRES RESUBMIT | 414 E BLACKLIDGE DR is not addressed with Unit 1 and Unit 2 with Pima County. Please contact Pima County Addressing at addressing@pima.gov or 520-724-9512 to properly address units. Additionally, a sub-records request will be required to change the addresses on the permit. Allow the full review time to complete this task as there may be other items to be addressed. For questions: Building_Official@tucsonaz.gov | ||
| 07/28/2025 | Light Residential Building Review (OIP) Express | REQUIRES RESUBMIT | TC-RES-0725-03602 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide a separate Comment Response Letter when submitting updated plans. Facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2018 IRC code compliance. The plans require sufficient detail for demonstrating minimum building code compliance for passing all progress inspections. Note the 2018 IRC reference on the plans. The plans require additional details for showing 2018 IRC compliance of construction performed without a permit. Provide plans showing all changes after the last completed permit at the ADU (unit #2) location. A record for unit #2 has not been identified or located. Provide the permit number for unit #2 development. Provide construction plans with sheet numbering in a single PDF file. Provide a response letter addressing each comment with location of change on the plans. Submit separate letter and plan set files. Provide a clear and concise construction plan set. Sample drawings are available for understanding details. Sample plans at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits SITE PLAN: 1. Show the location and size of the ADU electrical service panel, R106.1.1. Identify the utility lines requiring upgrade or replacement. 2. Show the square footage of ADU living space, R106.1.1. PLANS: 1. Show the functional name of each ADU room and location of the mini-split, R106.1.1. MECHANICAL PLAN: 1. Provide demand calculations in accordance with Manual J standards, M1401.3, M1601.1. Submit the Manual J report generated from identified compliant software. ELECTRICAL PLAN: 1. Provide the ADU panel schedule showing panel size, circuit numbers, ampacity, wire size and circuit general descriptions, E3404.13 & E3706.2. 2. Show the location of the proposed receptacle or disconnect switch, E3404.12. If you have any questions, please contact: PDSD-Residential@tucsonaz.gov City of Tucson Residential Plan Review Submit a corrected plan set at https://www.tucsonaz.gov/Departments/Planning-Development-Services ---------------------- |
||
| 07/28/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |