Description:
Adding a 30 amp max electrical circuit for a mini split on the ADU. Ran in EMT conduit using weatherproof connectors. Run will be on the roof then down the wall to the ADU, where it will meet a fused 30 amp disconnect box. 120V from second electrical panel, with a dedicated 30 amp breaker using 10 guage stranded THHN wire rated for conduit use.
Permit Reviews
Permit Number - TC-RES-0725-03602
Permit Status: Expired
Permit Description: Adding a 30 amp max electrical circuit for a mini split on the ADU. Ran in EMT conduit using weatherproof connectors. Run will be on the roof then down the wall to the ADU, where it will meet a fused 30 amp disconnect box. 120V from second electrical panel, with a dedicated 30 amp breaker using 10 guage stranded THHN wire rated for conduit use.
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 07/21/2025 | RESIDENTIAL SIMPLE REVIEW v.1 | 07/23/2025 | REQUIRES RESUBMIT |
| 07/28/2025 | RESIDENTIAL SIMPLE REVIEW v.2 | 07/28/2025 | REQUIRES RESUBMIT |
Outstanding Activity Conditions
Permit Number - TC-RES-0725-03602
Permit Status: Expired
Permit Description: Adding a 30 amp max electrical circuit for a mini split on the ADU. Ran in EMT conduit using weatherproof connectors. Run will be on the roof then down the wall to the ADU, where it will meet a fused 30 amp disconnect box. 120V from second electrical panel, with a dedicated 30 amp breaker using 10 guage stranded THHN wire rated for conduit use.
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 07/28/2025 | Please contact Pima County Addressing to resolve issue. Addressing@pima.gov or 520-724-9512 |
Conditions
Permit Number - TC-RES-0725-03602
Permit Status: Expired
Permit Description: Adding a 30 amp max electrical circuit for a mini split on the ADU. Ran in EMT conduit using weatherproof connectors. Run will be on the roof then down the wall to the ADU, where it will meet a fused 30 amp disconnect box. 120V from second electrical panel, with a dedicated 30 amp breaker using 10 guage stranded THHN wire rated for conduit use.
| Date | Description | Comments |
|---|---|---|
| 07/21/2025 | Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit is required prior to issuance of permit. The Affidavit form is available at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit. |