Permit Number: TC-RES-0723-06650
Parcel: 126190320

Review Status: Requires Resubmit

Review Details: RESIDENTIAL NEW DWELLING v.2

Permit Number - TC-RES-0723-06650
Review Name: RESIDENTIAL NEW DWELLING v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
09/26/2023 Bldg Permits - Post Review Express PENDING ASSIGNMENT
09/19/2023 Residential Building REQUIRES RESUBMIT TC-RES-0723-06650
PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval.

PROVIDE A COMPLETE PLAN SET showing the appropriate (2018 IRC) code referenced on the plans.

Separate the submitted files with construction plans and support documents in different files. Place the site plan within the construction plan set.

Provide a clear and concise construction plan set. Sample plans are available at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits

PLANS:

1. Any part of a roof projection extending into the 3-foot fire separation distance from the property line requires not less than one-hour fire-resistive construction on the underside, R302.1 (City of Tucson Amended). Consider updating detail #1 on sheet 8.2 with 5/8” Type ‘X’ gypsum board applied to the underside of the roof projection. The FireGuard product is not recognized without an Arizona engineer seal or a registered engineer report with the International Code Council, Inc.

2. Notate the requirement for deferred (sealed) truss plan submittal on the site plan, R106.1.

If you have any questions, please contact:
Ken Van Karsen
PDSD-Residential@tucsonaz.gov
City of Tucson Residential Plan Review

Submit a corrected plan set at https://www.tucsonaz.gov/Departments/Planning-Development-Services
09/26/2023 Site Zoning REQUIRES RESUBMIT FROM: Paul Camarena
PDSD Zoning Review Section

PROJECT: TC-RES-0723-06650
513 S CATALINA AV Zoning R-1

TRANSMITTAL DATE: September 26, 2023


COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

1.COMMENT: After comparing the aerials to the plot plan it has come to my attention that there is a possible non-permitted structure on the south portion of the site. Provide permit documentation Clarify if these structures are still on site if so please add to the site plan
If there are additional structures these comment are still applicable. Per UDC Article 6.6.3.E “The total gross floor area (gfa) of all accessory structures shall not exceed 50% of the gfa of the principal structure . Accessory structures less than 200 square feet gfa and accessory dwelling units are exempt from this requirement”. Based on the provided information, the proposed detached structure will exceed the 50% of the gfa. Options that are available to you are to downsize the structure to meet the applicable regulation, to attach the structure to the existing dwelling with a 5’ wide patio type structure which can support a 20 lb live load or a Board of Adjustment for Variance is required. Board of Adjustment requirements and application can be found at: https://www.tucsonaz.gov/files/pdsd/codes/Zoning_Administration_Application_BA_fillable.pdf. The Board of Adjustment is a separate submittal from the building plan and is submitted at: https://www.tucsonaz.gov/pdsd-filedrop, using the Submission Type “Zoning Administration”. Contact Wyatt Berger at wyatt.berger@tucsonaz.gov or Georgia Pennington at georgia.pennington@tucsonaz.gov if you have any questions about the Board of Adjustment.



If you have any questions about this transmittal, Contact Paul Camarena at (520)837-4986 or by email Paul.Camarena@tucsonaz.gov
09/01/2023 PDSD Application Completeness Express REVIEW COMPLETED