| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/30/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 06/25/2026 | Addressing Validation | REQUIRES RESUBMIT | For questions: PDSD-Permits@tucsonaz.gov There appears to be two units linked to this address. An address change request must be completed through the sub record of this permit to add correct unit number of the ADU to this permit. Once that request is submitted, please resubmit documents to reflect the updated address. Instructions can be found here to request change of address: https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/sub-records.pdf Step-by-Step instructions on how to resubmit: https://www.tucsonaz.gov/files/sharedassets/public/pdsd/documents/tdc-faq/new-pdfs/revisions-and-resubmittals.pdf |
||
| 06/30/2026 | Residential Building | REQUIRES RESUBMIT | TC-RES-0626-03424 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment updates; revisions are processed if changes occur after the permit is issued. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2024 International Residential Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. GENERAL REQUIREMENTS: The City of Tucson adopted the 2024 IRC with amendments and building ordinances for all dwellings. Provide a separate response letter addressing each comment with location of change on the plans. GENERAL COMMENTS: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Building-Codes 1. Show compliance with the Inclusive Home Design Ordinance adopted by the City of Tucson Ordinance #10463 on 10/16/2007. Notate accessible route, minimum door width, changes in floor elevation, door hardware, electrical outlet reach range, grab bar reinforcement, etc. SITE PLAN: 1. Show the utility meters and lines from the utility source to the building, R106.1.1. Identify the utility lines requiring upgrade or replacement. 2. Each dwelling building requires a street address and a separate permit, R319. Show Pima County assigned unit numbers at each dwelling on the site plan 3. Each dwelling unit should have an individual 3-foot clear space (including the roof projections) known as the fire separation distance for reducing fire spread to nearby buildings. Each dwelling unit should have an individual 3-foot clear space (including the roof projections) known as the fire separation distance for reducing fire spread to nearby buildings. Portions of buildings placed in a fire separation distance require one-hour fire-resistive construction in compliance with IBC Table 721.1(2). PLANS: 1. Notate a cool (white) roof finish (greater than 60 SRI) as required by the ADU provisions. 2. Show a maximum ½” floor elevation changes at a notated accessible route entrance on the floor plan, R106.1.1. Include all threshold conditions for a route from the exterior into the living space. 3. Roof projections attached to a dwelling require 6 feet of separation unless fire rated materials are included, R302.3. Provide a detail or notation showing compliance with 703.3 of the 2018 IBC. Consider a 1-hour rated wall at the carport where located near the primary dwelling roof overhang. Show the porch roof a minimum of 4-feet from the primary dwelling roof overhang and 1-hour rated material at the underside of the overhang. 4. Provide a minimum 6 mil polyethylene vapor retarder with joints lapped not less than 6 inches between the concrete floor slab and the base course or the prepared subgrade where a base course does not exist, R506.3.3. 5. Submit a completed plan set after DDO approval. If you have any questions, please contact: Kenneth.VanKarsen@tucsonaz.gov City of Tucson Residential Building Safety |
||
| 06/26/2026 | Residential Engineering | REQUIRES RESUBMIT | Permit Activity Number: TC-RES-0626-03424 (1st Review) Project: NEW CASITA/GUESTHOUSE/ADU - DDO ONLY Location: 2220 N ARENA VISTA AV Review Date: 6/26/2026 Reviewer: Marco Contreras – Engineering Associate - Site Engineering Reviewer Contact: Marco.contreras@tucsonaz.gov Related cases: Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed to ensure final approval from Site Engineering. To help speed up your resubmittal and facilitate shorter review timelines, please include a response letter along with your updated plans and any supporting calculations. In your response letter, address each comment individually and explain what changes were made and where they can be found in the plans. Please do not mark or highlight changes in the drawings at this stage — revision markups are only used after a permit has been issued. Submit your response letter and updated plan set as two separate files. Site Engineering Review Comments: 1. The City of Tucson Inclusive Home Design Ordinance requires all new dwellings — including ADUs, single-family residences, and duplexes — to provide an accessible route connecting the public street, sidewalk, or driveway to an accessible entrance of the home. This pathway must be shown, dimensioned, and labeled on the plans. What this means in plain terms: There needs to be a clearly defined, walkable path from where a person arrives (the street, sidewalk, or driveway) all the way to a usable door of the home — one that someone using a wheelchair or mobility aid could navigate without barriers. An exterior accessible route that shall conform to 2017 ICC A117.1 Sections 402 and 403 and City of Tucson Inclusive Home Design Ordinance. The current plans to no reference a material nor show a connection to ROW sidewalk or Parking area proposed. Ensure dimension the path at the minimum 4-feet required. Reference: https://www.tucsonaz.gov/files/sharedassets/public/v/1/city-services/planning-development-services/documents/inclusivehomedesignordinance.pdf Action Items — Show the following on your plans: • Draw and label the path as "Accessible Route" • Provide a minimum clear width of 4 feet with a width call-out on the plans • Note the proposed running slope (must not exceed 5% / 1:20) and cross slope (must not exceed 2% / 1:50) • Identify the accessible entrance the route leads to Acceptable Accessible Route compositions include: • Portland cement concrete (PCC) • Broom Finished concrete • Brick or unit pavers (Only if set on a stable cement base with no gaps exceeding ½”) • Concrete pavers on concrete base (Same joint and evenness requirements as brick) • Flagstone: must be mortared – loose set does not qualify • Any surfaces equivalent in smoothness, hardness, and durability NOTICE: Decomposed granite (DG) is not permitted for required accessible routes, even if compacted |
||
| 06/29/2026 | Residential Zoning | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Erick Bieber Planning & Development Services Department – Zoning Review Section PROJECT: TC-RES-0626-03424 – Residential Building 2220 N Arena Vista Ave, Tucson, AZ 85715 Residential ADU - Casitas (1st Review) TRANSMITTAL DATE: June 29th, 2026 This site is located in the RX-2 zone (UDC 4.7.7). A single-family residence is a permitted use in this zone (Table 4.8-1) subject to Use Specific Standards 4.9.7.B.6, .8, & .9 & 6.6.3. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Correct plans, as noted in the comments below, along with a response letter indicating how all Site Zoning comments were addressed. 1. (Comment) Per UDC 6.6.3.B.6, the minimum side and rear yard setback for an accessory dwelling unit is 5’. The proposed ADU has a side yard setback of 3’. A Design Development Option (DDO) is required to reduce the required side-yard setback. Please submit a DDO application under the Zoning Modifications sub-record that has been created. For additional questions regarding DDOs, contact Mark Castro at Mark.Castro@tucsonaz.gov. The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code For questions regarding Zoning comments, please contact me at: Erick.Bieber@tucsonaz.gov |
||
| 06/25/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |