Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.1
Permit Number - TC-RES-0524-02702
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
06/03/2024 | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
05/15/2024 | Residential Building | REQUIRES RESUBMIT | TC-RES-0524-02702 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide a separate Comment Response Letter when submitting updated plans. Facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2018 IRC code compliance with component sizes. The plans require sufficient detail for demonstrating an awareness of minimum building code compliance for passing all progress inspections. Provide a response letter on separate file with submitting the updated construction plan set. Consider using a design professional if unfamiliar with construction documentation. The construction plan set should show all proposed features for the proposed building with utilities. Place page numbers on each sheet of the construction plan set. Provide a clear and concise construction plan set. Sample Addition plans are available at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits SITE PLAN: Provide a site plan showing utilities for the dwelling, R106.1.1. Show the location of all utility lines from property line to building(s) along with required alterations. FLOOR PLAN: Provide a complete floor plan showing structural separation from the mobile home. STRUCTURAL PLANS: 1. Provide a complete plan set showing materials and fastener sizes with 2018 IRC prescriptive compliance or provide an Arizona professional stamped plan set showing performance compliance with wind loading conditions, R301.1. 2. The proposed Patio Cover may be sited within the 3’ fire separation distance from a property line. Show compliance with R302.1 (City of Tucson Amended) by providing a wall with one-hour rated materials prescribed in IBC Table 721.1(2), Items 15-1.1 to 16-1.3, R106.1 or remove any structure closer than 3 feet to the property line. SECTIONS - DETAILS: 1. Provide a complete cross-section detail showing proposed material sizes and ratings, R106.1. 2. Provide a structure section showing existing and proposed features including a foundation, framing, sills, anchoring, sheathing and insulation, R106.1. 3. Provide a complete cross-section detail showing type and size of framing, exterior wood siding, insulation, interior sheathing, and pressure treated sill anchored with ½” x 10” bolts. Show the wall assembly with a 6” clearance above the ground or 2” clearance above an exterior concrete surface, R317.1 item 5. 4. Clarify the placement of ceiling/roof insulation for determining the need for attic ventilation, R806. Attic space outside of the thermal barrier requires a ventilation calculation for showing the attic vent opening size using 1 to 150 of attic area in compliance with R806.2 or an unvented roof assembly requires an air-impermeable rigid insulation material with a minimum R-5 value applied correctly to either side of the roof sheathing, R806.5. Show a roof design with insulation types and minimum thickness for meeting the condensation control requirement and the minimum total insulation value of R-30. PLUMBING PLANS: 1. Provide complete plumbing plans showing any changes with 2018 IRC compliance, R301.1. 2. Tucson Water Department limits flow rates for each water meter size in compliance with P2903.7. Show an appropriate yard pipe for supporting the existing and proposed water demand. MECHANICAL PLANS: 1. Show heating/cooling facilities in all habitable rooms, R303.9. 2. Show bathroom (without a window) exhaust fan locations with minimum 50 CFM rating and duct to the exterior, R303.3 and M1505. ELECTRICAL PLANS: 1. Designate the circuit number at the location of each light fixture, receptacle, appliance, and equipment disconnect switch, E3404.12. 2. Show a smoke alarm in each bedroom and outside the doorway in the immediate vicinity, R314.3. 3. Show receptacle outlets, E3901.2. 4. Show at least one wall-switch-controlled lighting outlet providing illumination on the exterior side of each egress door having grade level access R3903.3. 5. Notate interior 15A & 20A circuits serving outlet locations (except garage, kitchen, and bathrooms) including receptacles, lights, and smoke detectors with combination type arc-fault circuit interrupters, E3902.16. OUTDOOR LIGHTING CODE Show the proposed fixture as full cut-off FCO style or provide an Outdoor Lighting Calculation including all exterior fixtures on the property for determining exterior lighting limits. Show full cutoff fixtures were located within 25 feet from the property line OLC 401.3.3. If you have any questions, please contact: PDSD-Residential@tucsonaz.gov City of Tucson Residential Plan Review Submit a corrected plan set at https://www.tucsonaz.gov/Departments/Planning-Development-Services |
||
06/03/2024 | Site Engineering | REQUIRES RESUBMIT | 1. Please provide a map of the parcel indicating the location of Unit 16. Mike Ortiz michael.ortiz@tucsonaz.gov |
||
05/31/2024 | Site Zoning | REQUIRES RESUBMIT | FROM: PDSD Zoning Review Section PROJECT: TC-RES-0524-02702 1681 W PRINCE RD Unit: 16 – R-1/C-2 Loft Shed Addition to Existing Mobile Home (1st Review) TRANSMITTAL DATE: May 31, 2024 COMMENTS: Resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This site is located in the R-1C-2 zone (UDC 4.7.8/4.7.21). A mobile home park is not a permitted use in this zone (Table 4.8-2/4.8-4). This site is considered non-conforming for the use. 1. Provide a mobile home setup plan that clearly shows where the proposed is within the mobile home park. This plan shall clearly show the required perimeter yard setbacks to any exterior property lines and the distances to all adjacent structures. Contact Loran Shamis at (520) 837-2242 or email Loran.Shamis@tucsonaz.gov for templates for the mobile home setup plans. 2. Provide fully dimensioned building elevations with the next submittal. 3. Provide a full floor plan that clearly shows what is proposed within the loft shed. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
||
05/03/2024 | PDSD Application Completeness | REVIEW COMPLETED |