Permit Number: TC-RES-0523-05587
Parcel: 122161930

Address:
2026 N BAXTER DR

Review Status: Requires Resubmit

Review Details: RESIDENTIAL NEW DWELLING v.1

Permit Number - TC-RES-0523-05587
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
06/26/2023 Bldg Permits - Post Review Express PENDING ASSIGNMENT
06/26/2023 Residential Building REQUIRES RESUBMIT TC-RES-0523-05587
PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval.

PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2018 IRC code compliance with component sizes. The plans require sufficient detail for demonstrating an awareness of minimum building code compliance for passing all progress inspections.

PLANS - DETAILS:

1. Clarify the overtyped description of 2/A-7.
2. Update the description of 1/A-9.

PLUMBING PLANS:

1. Show gas pipe sizes in compliance with connected demand, G2413.3 & Table G2413.4(1). Provide a gas line isometric or table for showing the BTU demand and developed length of line to each gas appliance.

MECHANICAL PLANS:

1. Show the (dryer) exhaust opening not less than 3 feet from the property line, M1504.3.

ELECTRICAL PLANS:

1. Show Bathroom receptacles with a separate 20 AMP dedicated circuit, E3703.4 and E3901.6.
2. Show one 20 AMP branch circuit in the laundry area; this circuit may not serve other locations, E3703.3 and 3901.8.

If you have any questions, please contact:
Ken Van Karsen
PDSD-Residential@tucsonaz.gov
City of Tucson Residential Plan Review

Submit a corrected plan set at https://www.tucsonaz.gov/pdsd
06/09/2023 Site Zoning REQUIRES RESUBMIT ZONING REVIEW TRANSMITTAL

FROM: Wyatt Berger
Lead Planner

PROJECT: TC-RES-0523-05587
2026 North Baxter Avenue – R-1
Addition (1st Review)

TRANSMITTAL DATE: June 9, 2023

Please resubmit revised drawings with a detailed response letter stating how all Zoning Review Section comments were addressed.

The site is in the R-1 zone (UDC 4.7.8). A single-family residence is permitted in the R-1 zone, subject to use-specific standards 4.9.7.B.5-.9.

1. Remove the 41 square foot path and all porches from the lot coverage calculation on the site plan. Roofed areas, open on at least one side, are excluded from lot coverage (UDC 6.4.3.C.1.a).

2. Show all structures on the site plan. A shade sail that is attached to the residence appears in aerial photography beginning in 2019. The shade sail does not meet perimeter yard requirements from the south lot line and requires a Board of Adjustment variance. The shade sail shall be removed from the site to avoid the Board of Adjustment variance process. Show the existing carport as well.

If you have any questions about this transmittal, contact me at Wyatt.Berger@tucsonaz.gov or at 520-837-4951.
06/02/2023 PDSD Application Completeness Express REVIEW COMPLETED
06/06/2023 Site Engineering REVIEW COMPLETED