Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-RES-0523-05190
Parcel: 130191630

Address:
4621 E 32ND ST

Review Status: Requires Resubmit

Review Details: RESIDENTIAL SOLAR v.1

Permit Number - TC-RES-0523-05190
Review Name: RESIDENTIAL SOLAR v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
06/08/2023 Bldg Permits - Post Review Express PENDING ASSIGNMENT
06/08/2023 Light Residential Building Review (OIP) REQUIRES RESUBMIT Permit Review TC-RES-0523-05190 (4621 E 32ND ST TUCSON, AZ 85711)
Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received.
Code reference, 2018 International Residential Code (IRC).

1. Show access and working space around all electrical equipment for safe operation and maintenance of equipment, E3405.1.
2. Provide a panelboard clear working space of 30” wide x 36” deep, E3405.2.
3. Show the mast height on the electrical riser diagram providing 8’ clearance above the Porch roof, E3604.2.1.
4. Provide a code compliant drip loop at the TEP service line connection to the weather head, E3605.9.5.

Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov
05/17/2023 PDSD Application Completeness Express REVIEW COMPLETED