Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL SOLAR v.1
Permit Number - TC-RES-0523-05190
Review Name: RESIDENTIAL SOLAR v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/08/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 06/08/2023 | Light Residential Building Review (OIP) | REQUIRES RESUBMIT | Permit Review TC-RES-0523-05190 (4621 E 32ND ST TUCSON, AZ 85711) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2018 International Residential Code (IRC). 1. Show access and working space around all electrical equipment for safe operation and maintenance of equipment, E3405.1. 2. Provide a panelboard clear working space of 30” wide x 36” deep, E3405.2. 3. Show the mast height on the electrical riser diagram providing 8’ clearance above the Porch roof, E3604.2.1. 4. Provide a code compliant drip loop at the TEP service line connection to the weather head, E3605.9.5. Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov |
||
| 05/17/2023 | PDSD Application Completeness Express | REVIEW COMPLETED |