Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.1
Permit Number - TC-RES-0523-05178
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
05/25/2023 | Site Zoning | APPROVED | |||
05/19/2023 | Site Engineering | NOT REQUIRED | |||
06/15/2023 | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
06/15/2023 | Residential Building | REQUIRES RESUBMIT | Permit Review TC-RES-0523-05178 (4988 E SCENIC PEAK WY TUCSON, AZ 85706) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2018 International Residential Code (IRC). https://www.tucsonaz.gov/files/pdsd/pdfs/Porch_Sample.pdf 1. Provide ceiling joist sizes and spacing in compliance with Table R802.4.1(2). 2. 4x8 beam is undersized for the given span, Show a beam size with appropriate load carrying capacity, R301.1. 3. Notate and specify the size, spacing and length of anchor bolts for ledger connection to the existing wall, R801.2. 4. Show roof (uplift resistance) fasteners (H2.5) with appropriate uplift capacity, R802.11 amended. 5. Provide a complete cross-section detail from foundation to roof assembly with a respective notation of all hardware, hangers post caps, connecters, etc, indicated on the plan or elevation, R106.1.1. See https://www.tucsonaz.gov/files/pdsd/pdfs/Porch_Sample.pdf for example cross-section details. 6. Completely detail all post connections from post base to the foundation, post to beam and beam to rafters, R301.1. 7. Show or notate a 6” minimum separation of untreated exterior posts above finished grade or metal post base with 1” space above concrete, R317.1.4 exception 1. 8. Provide footings for each post in compliance with R403.1.1, concrete footings of minimum 12” width and 12” below the undisturbed ground surface, with minimum of one #4 rebar. Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov |
||
05/15/2023 | PDSD Application Completeness | REVIEW COMPLETED |