Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-RES-0426-01841
Parcel: 13701001F

Address:
5050 S 1ST AV

Review Status: Requires Resubmit

Review Details: RESIDENTIAL NEW DWELLING v.1

Permit Number - TC-RES-0426-01841
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
04/28/2026 Bldg Permits - Post Review Express PENDING ASSIGNMENT
04/16/2026 Residential Building REQUIRES RESUBMIT TC-RES-0426-01841
PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment updates; revisions are processed if changes occur after the permit is issued.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2024 International Residential Code and 2018 International Energy Conservation Code. The 2024 International Energy Conservation Code takes effect July 1st. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval.

GENERAL REQUIREMENTS:

The City of Tucson adopted the 2024 IRC with amendments and building ordinances for all dwellings.

Provide a separate response letter addressing each comment with location of change on the plans.

GENERAL COMMENTS:
https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Building-Codes

1. Show compliance with the Inclusive Home Design Ordinance adopted by the City of Tucson Ordinance #10463 on 10/16/2007. Notate accessible route, minimum door width, changes in floor elevation, door hardware, electrical outlet reach range, grab bar reinforcement, etc.
2. Plans submitted for a newly constructed one- or two-family dwelling after July 1, 2009 require a solar photo-voltaic system, or future installation preparation City of Tucson Ordinance #10549 . Show a minimum 300 SF clear solar-ready zone on a roof or framing plan, T103.3.
3. Plans submitted for a newly constructed one- or two-family dwelling after June 1, 2010, require gray water utilization or preparation, Ordinance #10579/11089 revised July 9, 2013. The ordinance revision now requires a gray drain line discharge from one fixture for a one-story dwelling. Additional gray fixture drains are optional. Show a second clothes washer standpipe plumbed to an exterior wall above grade when feasible, or a bathing fixture drain looped 3’ beyond an exterior wall below grade before connection to the building drain. Use the appropriate detail at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Building-Safety/Water-Energy-Conservation Gray Water Illustrations
4. Show compliance with the Electric Vehicle Supply Equipment Ordinance adopted by the City of Tucson Ordinance #11844 on 6/22/2021. Include a 40 ampere 240-volt dedicated branch circuit with a NEMA 14-50R receptacle for charging an electric vehicle at a proposed parking space.

PLANS:

1. Show a maximum ½” floor elevation changes at a notated accessible route entrance on the floor plan, R106.1.1. Include the threshold condition at the vehicle doorway or an exterior hinged door when the garage is used for the accessible route.
2. Provide a minimum 6 mil polyethylene vapor retarder with joints lapped not less than 6 inches between the concrete floor slab and the base course or the prepared subgrade where a base course does not exist, R506.3.3.
3. Show braced wall panel compliance for (narrow) framed walls with a garage door opening, Table R602.10.5. For prescriptive braced wall structures show a portal frame with hold-downs PFH method, Figure R602.10.6.2, or a portal frame at garage door PFG method, Figure R602.10.6.3, or a continuously sheathed portal frame CS-PF method, Figure R602.10.6.4.
4. Show the location of a minimum 22” x 30” attic access. Attic access is required for areas exceeding 30 SQ FT with a minimum of 30” of headroom and located in a hallway or readily accessible space, R807.1.

PLUMBING PLANS:

1. Show the water heater rating/capacity for consistence with an electrical circuit capacity or gas pipe size, R106.1.1. Show all required utility lines.
2. Show a gas pipe sized in conformance with Table G2413.4(1) for a gas water heater.

ELECTRICAL PLANS:

1. Remove outdated 2018 IRC code references from note #8 & 9.
2. Specify high-efficacy luminaires with an efficacy not less than 45 lumens per watt or lamps with efficacy not less than 65 lumens per watt (LED devices), N1104.1. Update the 90% note at the upper left corner.
3. Show the Electric Vehicle Supply Equipment 40 ampere 240-volt dedicated branch circuit with a NEMA 14-50R receptacle and label the circuit “EV Ready” and locate the receptacle at a parking area, N1104.2.1. Include the Electric Vehicle load entry (typically 7680 watts) in the electrical load calculations (continuous demand) like the HVAC entry, N1104.2.2.
4. Show a surge-protective device (SPD) as an integral part of or placed immediately adjacent to the service equipment, E3606.5.
5. Provide GFCI protection for appliance receptacle outlets, E3902.12. Include:
1. Drinking water coolers
2. High pressure spray washing machines
3. Sump pumps
4. Dishwashers
5. Electric ranges
6. Wall-mounted ovens
7. Counter-mounted cooking units
8. Clothes dryers
9. Microwave ovens

INTERNATIONAL ENERGY CONSERVATION CODE:

1. Energy Certificate: (Mandatory) place near the indoor furnace or in utility room, N1101.14. Add notation to plans.

Please contact the plans reviewer if you have any questions:
Kenneth.VanKarsen@tucsonaz.gov
City of Tucson Residential Building Safety
04/28/2026 Residential Engineering REQUIRES RESUBMIT Permit Activity Number: TC-RES-0426-01841 (1st Review)
Project: Single Family Residence
Location: 5050 S 1ST AV
Review Date: 4/28/2026
Reviewer: Marco Contreras – Engineering Associate - Site Engineering

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter review time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment updates; revisions are processed if changes occur after the permit is issued. Provide a response letter addressing each comment with location of change on the plans. Submit the separate response letter and plan set files.

City of Tucson Code: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes
Floodplain Code: https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az/0-0-0-19333

Site Engineering Review Comments:
1. As the proposed development is a new dwelling (ADU, SFR, Duplex, Etc), Per the City of Tucson Inclusive Home Design Ordinance: https://www.tucsonaz.gov/files/sharedassets/public/v/1/city-services/planning-development-services/documents/inclusivehomedesignordinance.pdf, all new dwellings and units have a requirement to provide an “accessible route from public and common areas, including, but not limited to, a driveway or public street or sidewalk”. Draw, dimension, and label an accessible route from the driveway, sidewalk, or street to an accessible entrance.
a. Refer to Technical Standards Manual Section 7-01.4.3 for sidewalk/pathway specifications including the minimum 4ft-width and composition minimums.
b. Action Items: Provide a width call-out, proposed slope, and label the walkway as the “Accessible Route” leading to the new home entrance
2. The SFR proposed at 5050 S 1ST AV falls within a City of Tucson Flood hazard zone associated with the Old Nebraska Wash that runs South to North along the West of the property. The Rodeo Wash, which carries a WASH designation, also runs SE to NW north of the property. As there is no available data in regards to base flood elevations or specific flows, it will require the submission of a separate floodplain use (FPU) permit application with Elevation Certificate
a. The FPU permit is a separate permit that can be submitted within the sub-records of this residential permit through TDC Online.
3. In accordance with the City of Tucson floodplain code/ordinance, a Development Package (Grading Permit) required due to development within a Floodplain/Flood Hazard area. Tucson Code chapter 26, section 26-8.3.b and 26-8.d.2 As the Grading will be taking place within the floodplain, a civil engineer will need to stamp the associated grading plans to verify the necessary fill pad dimensions required. All subsequent site plans and grading plans shall have the limits and surface elevations associated with the floodplain delineated.
a. The grading permit submission will require a hydrology study prepared for by a registered Civil Engineer and/or hydrologist. The report shall determine the limits of the floodplain associated with Nebraska Wash, associated base flood elevations, and a determined required finish floor elevation necessary for the new home.
b. The project (grading plan) will need to factor in Rodeo Wash – as it carries a WASH designation, this project will be subject to WASH standards as stipulated in Section 29 & TSM 4-02.0.0. It will be required that the “Study Area” associated with Rodeo Wash be delineated/shown on all provided plan sets. Encroachment into this area will carry additional requirements.
4. Site Engineering will be unable to approve permit TC-RES-0426-01841 until the associated FPU permit and associated grading permit are approved and issued. It is recommended that the FPU and grading permit process be started and achieve approval and issuance prior to the resubmission of this permit to ensure no project delays and review overlap.


If you have any questions or concerns, please contact Marco Contreras at Marco.contreras@tucsonaz.gov
04/23/2026 Residential Zoning REQUIRES RESUBMIT PDSD TRANSMITTAL
FROM: Roxanne Johnston
Planner
PROJECT: TC-RES-0426-01841
5050 S 1st Av., Tucson, AZ 85714
SFR (1st Review)

TRANSMITTAL DATE: 04/23/2026

This site is located within the R-2 Zone (UDC 4.7.9). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.6, .9, & .10.

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Please correct plans, as noted in the comments below, along with a response letter indicating how all Site Zoning comments were addressed.

Comment 1: Ordinance No. 12219, an amendment to the Unified Development Code, went into effect January 1, 2026. Per UDC 7.6.10.A, (as amended), landscaping is required for all new single family residential, middle housing development and accessory dwelling units. For the purposes of the UDC and this review, a duplex is considered two SFRs.

UDC 7.6.8. NEW SINGLE FAMILY, MIDDLE HOUSING, AND ACCESSORY DWELLING UNITS
A. The following landscaping is required for all new single family residential, middle
housing development, and accessory dwelling units. These requirements do not apply to new single family residential dwellings within subdivisions of 5 or more units.
1. One canopy tree is required for every 1,000 square feet of gross floor area of
the development project.
2. Vegetative groundcover is required within the front yard setback per the
calculation below.
(X Linear feet of Street Frontage) – (Y Curb cut width) x (5 Foot Depth) = Z Square Feet of vegetative groundcover. An example, using a parcel with 115 feet of street frontage and a 15-foot curb cut: (115 Linear Feet of Frontage) – (15 curb cut) X (5 Foot Width) = 500 Square Feet of vegetative groundcover required within the front yard setback.
Parcels with less than 30 linear feet of street frontage may place the required
groundcover in alternate locations indicated on the site plan.
[…]
3. Plants must be low to very low water use with a hardiness rating of 15 degrees
Fahrenheit or lower and non-invasive. Options are listed in Section 5-02.5.0 of
The Technical Standards Manual. Exceptions to these criteria or plants that are not listed in Section 5-02.5.0 of the Technical Standards Manual, may be
approved by the PDSD Landscape Architect.
B. Required landscaping must be located as follows:
1. A minimum of fifty percent of the required canopy trees must be located within
The front yard setback area.
a. Exception: If site constraints prevent new tree placement in a front yard,
five shrubs may be substituted per required tree. Required trees must still
be placed elsewhere on the site. Shrubs used as a substitute plant
material for the required tree shall range from three feet in height by three
feet in width, or larger. Shrubs must follow the relevant spacings from
utility lines in section 5-01.5.11of the Technical Standards Manual, but can
be planted one radius of their mature width from foundations, enclosed
sidewalks, sidewalks, and curbs.
b. Exception: The tree required for an accessory dwelling unit may be
placed anywhere on site.
2. Trees may be planted at varying distances apart.
3. Required landscaping is not restricted to the first 10 feet onto the property from
the existing or future right-of-way line.
4. Newly planted trees must be placed at a minimum distance from existing or
proposed City of Tucson-owned or private utility-owned lines, as found in section
5-01.5.11 of the Technical Standards Manual. Tree plantings are not permitted in
El Paso Gas Easements or under overhead power lines.
5. Trees shall be placed a minimum of ten feet from the center of the tree trunk to
any enclosed structure.
6. Trees shall be placed a minimum of five feet from the back of the sidewalk or
curb. If this standard cannot be met, then root barriers are required and must be
illustrated on the submitted construction plans.
7. Trees must be planted in a six-to-nine-inch depressed planting area of at least
50 square feet (four-foot radius, or alternatives as proposed) and at least ten feet
away from a building foundation.
8. Existing, established trees on property, at least 4 inches trunk diameter at
chest height, located at least ten feet from the foundation or with an unobstructed
dripline at maturity, shall count toward this requirement (See Figure 7.6.2.B in the amended ordinance – link provided below). The root systems of existing trees used for this requirement must be protected from soil compaction during construction using perimeter protective fencing around the dripline. Established trees are not required to have a depressed planting area. Existing shrubs and vegetative groundcover may also be used toward the required landscaping.
Figure 7.6.2-B: Obstructed and unobstructed driplines on various size trees,
located 10 feet from an existing structure
C. Vegetation shall be established, maintained, and sustained throughout its life in
support of the City’s tree count, climate, and walkability goals. One of the following two options may be used:
1. Drip or bubbler irrigation with backflow protection. A simple irrigation system
can be part of the domestic water supply for the residence.
2. Alternate methods, such as rainwater harvesting, hand watering, and
greywater systems, as proposed by the property owner and approved by the
PDSD Landscape Architect.
D. Proposed landscaping and related items can be included in a residential plot plan; a
Landscape Plan is not required.

Comment 2: Per the City of Tucson Inclusive Home Design Ordinance : https://www.tucsonaz.gov/files/sharedassets/public/v/1/city-services/planning-development-services/documents/inclusivehomedesignordinance.pdf all new dwellings are required to provide a 4’-wide “accessible route from public and common areas, including, but not limited to, a driveway or public street or sidewalk”.

Comment 3: Correct the setbacks listed on A1.0. Per UDC Table 6.3-2.A, as amended through Ordinance No. 12219, rear and side setbacks for interior lots in the R-2 zone are 5’. Front setbacks are 20’.

Comment 4: Additional comments may be forthcoming depending on responses to zoning review comments and plans submitted for the next review.

The City of Tucson Unified Development Code (currently being updated) may be accessed at this site: https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az_udc/0-0-0-1

Ordinance No. 12219, adopted January 1, 2026: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/middle-housing/middle-housing-ordinance-clean.pdf

For questions regarding Zoning comments, please contact me at: roxanne.johnston@tucsonaz.gov
04/15/2026 PDSD Application Completeness Express REVIEW COMPLETED