Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL SOLAR v.1
Permit Number - TC-RES-0425-01919
Review Name: RESIDENTIAL SOLAR v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/19/2025 | Site Zoning - Standard | APPROVED | |||
| 05/13/2025 | Site Engineering - Standard | NOT REQUIRED | |||
| 05/19/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 05/07/2025 | Light Residential Building Review (OIP) - Standard | REQUIRES RESUBMIT | Permit Review TC-RES-0425-01919 (1706 E COPPER ST TUCSON, AZ 85719). Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2018 International Residential Code (IRC). Structural Review: For ground mounted systems, the Foundation must be engineered/designed, sealed and signed by an Arizona Registered engineer, to support the weight of the system and to resist the wind uplift, R106.1, R324.4.1.2. Provide structural sheets and calculations Sealed and signed by an Arizona registered Engineer. Provide a list of any special inspections required including SPECIAL INSPECTION FOR PILING, DRILLED PIERS AND CAISSONS IS REQUIRED. Provide a Special Inspection Certificate, with Parts A and B completed. https://www.tucsonaz.gov/files/sharedassets/public/v/1/city-services/planning-development-services/documents/special_inspection_certificate.pdf Electrical Review: Provide a Grounding Electrode System at the detached structure per NEC 690.47. Show the Grounding Conductor’s connection at the modules, mounting and metal support structure. Show grounding details for the mounting equipment and metal support frame, NEC690.43. |
||
| 04/14/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |