Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.2
Permit Number - TC-RES-0424-02393
Review Name: RESIDENTIAL NEW DWELLING v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/29/2024 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 10/01/2024 | Residential Building | REQUIRES RESUBMIT | TC-RES-0424-02393 2nd PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment updates; revisions are processed if changes occur after the permit is issued. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. GENERAL REQUIREMENTS: The City of Tucson adopted the 2018 IRC with amendments on 1/1/2019. Show the current code reference on sheet A-1. Provide a response letter addressing Zoning, Engineering and Building comments on a separate file with submitting the updated construction plan set. Remove the letter from the construction plan set. Each dwelling unit with kitchen requires a separate Pima County assigned street address after Zoning approval, R319. Show Pima County assigned unit numbers at each dwelling on the site plan. https://www.pima.gov/1010/Addressing-Frequently-Asked-Questions PLANS: 1. Notate a cool (white) roof finish (greater than 60 SRI) as required by the ADU provisions. 2. Show a maximum ½” floor elevation changes at a notated accessible route entrance on the floor plan, R106.1.1. Include all threshold conditions for a route from the exterior into the living space. 3. Provide manufacturer’s calculations and data for pre-engineered trusses dated and wet-sealed by an engineer who is registered in Arizona, or notate the requirement for deferred submittal, R106.1. ELECTRICAL PLANS: 1. Provide a consistent (100 AMP) sub panel rating on both the plan and panel schedule, E3602.1 & E3603.1. 2. Provide the appropriate wire size at circuit #15, E3601.6.1 & E3706.2. If you have any questions, please contact: PDSD-Residential@tucsonaz.gov City of Tucson Residential Plan Review Submit a corrected plan set at https://www.tucsonaz.gov/pdsd |
||
| 10/23/2024 | Site Engineering | REQUIRES RESUBMIT | 1. A floodplain use permit is required before this building permit can be approved. Mike Ortiz michael.ortiz@tucsonaz.gov |
||
| 10/29/2024 | Site Zoning | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Fernando Garcia, Planner, Site Zoning PROJECT: TC-RES-0424-02393 422 N WILSON AV. – R-1 New Accessory Dwelling Unit (2nd Review) TRANSMITTAL DATE: October 29, 2024 COMMENTS: Resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This site is located in the R-1 zone (UDC 4.7.8). A single-family residence with an accessory dwelling unit (ADU) is permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5 - .9 & 6.6.3. 1. Comment not addressed from prior review. Permit T18CM02027 Enclose Patio and Reframe Roof was never completed and currently is in expired status. A Finals only permit will need to be applied for and the inspections will need to be approved prior to approval of this plan. Contact Joseph Conrad at (520 37-5349 or Joseph.Conrad@tucsonaz.gov for requirements. 2. COMMENT: Lot coverage calculations do not include open porches, ramadas, or breezeways. Keep these calculations on the plan, but separate them from the lot coverage calculations. Recalculate lot coverage. 3. COMMENT: Label distance between main residence and new ADU structure in the breezeway area and between the ADU structure and the garage (both between walls and between overhangs). If you have any questions about this transmittal, please contact Fernando Garcia at fernando.garcia2@tucsonaz.gov. |
||
| 09/23/2024 | PDSD Application Completeness Express | REVIEW COMPLETED |