Permit Number: TC-RES-0423-04272
Parcel: 136283540

Review Status: Requires Resubmit

Review Details: RESIDENTIAL NEW DWELLING v.1

Permit Number - TC-RES-0423-04272
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
05/02/2023 Site Zoning APPROVED
04/17/2023 Site Landscape NOT REQUIRED
05/09/2023 Bldg Permits - Post Review Express PENDING ASSIGNMENT
05/09/2023 Residential Building REQUIRES RESUBMIT 1. Show compliance with R310 providing egress from the existing bedroom with minimum net clear opening area of 5 SQ FT. Sheet #2 shows an existing window removal. Verify that this room has another egress window or show the installation of a new egress window.
2. Protection of all interior 15A & 20A circuits serving outlet locations (except garage, kitchen, and bathrooms) including receptacles, lights and smoke detectors require combination type arc-fault circuit interrupters, E3902.16.
3. An unvented roof assembly requires an air-impermeable rigid insulation material with a minimum R-5 value applied correctly to either side of the roof sheathing, R806.5. Show a roof design with insulation types and minimum thickness for meeting the condensation control requirement and the minimum total insulation value of R-38 or R-30 when extended over the wall top plate for additions under 500 SF. Show a R-5 layer of foam board against the roof deck on sheet #5.
04/12/2023 Fire New Construction REVIEW COMPLETED
04/11/2023 PDSD Application Completeness Express REVIEW COMPLETED
04/20/2023 Site Engineering REVIEW COMPLETED