Permit Number: TC-RES-0326-01109
Parcel: 116181390

Review Status: Requires Resubmit

Review Details: RESIDENTIAL ADU v.1

Permit Number - TC-RES-0326-01109
Review Name: RESIDENTIAL ADU v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
03/06/2026 Residential Engineering APPROVED
03/18/2026 Bldg Permits - Post Review Express PENDING ASSIGNMENT
03/06/2026 Addressing Validation REQUIRES RESUBMIT For questions: PDSD-Permits@tucsonaz.gov

The permit and plan show to be for an Accessory Dwelling Unit (ADU) and requires to be separately addressed. It appears there are already 3 units linked to this parcel. Please submit a change of address request through the sub records of this permit to add the unit number of the ADU to this permit. Once the change of address request is submitted, please resubmit your plans and all supporting permit documents to reflect the updated address for the ADU.

Instructions can be found here to request change of address: https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/sub-records.pdf
03/18/2026 Residential Building REQUIRES RESUBMIT Please review the comments below and re submit when plans have been corrected. Please provide a letter that states where the comments have been addressed.
1. Please show a vapor barrier under the concrete slab. R506.3.3 Vapor retarder.
2. A unvented roof assembly requires an air-impermeable rigid insulation material with a minimum R-5 value applied correctly to either side of the roof sheathing, R806.5. Identify the ventilation requirements and insulation types for complying with the condensation control issues.
3. Garages beneath habitable rooms require separation from all overhead habitable rooms by not less than 5/8” type X gypsum board or equivalent. Also, ½” GWB is required on supporting walls, Table R302.6
4. Provide makeup air of not less than 100 square inches where a clothes dryer is placed in a closet, M1502.6.1. (Transfer grille, jump duct, CFM make up, no door)
5.E3606.5 Surge protection: all services supplying dwelling units shall be provided with a surge-protective device (SPD) installed in accordance with Sections E3606.5.1 through E3606.5.3.
5.Show garage opening narrow panels with fastening details using a prescriptive method at Figure R602.10.6.3
03/17/2026 Residential Zoning REQUIRES RESUBMIT PDSD TRANSMITTAL

FROM: Erick Bieber
Planning & Development Services Department – Zoning Review Section

PROJECT: TC-RES-0326-01109
130 N Melrose Ave, Tucson, AZ 85745
Residential ADU - Casitas (1st Review)

TRANSMITTAL DATE: March 17th, 2026

This site is located in the R-2 zone (UDC 4.7.9). An accessory dwelling unit is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.6, 8 & 9 and 6.6.3.

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Correct plans, as noted in the comments below, along with a response letter indicating how all Site Zoning comments were addressed.

1. (Comment) As of January 1, 2026, basic landscaping is required for all new 1-4 unit residential projects per Ordinance 12219, the Middle Housing Code Amendment. Proposed landscaping and related items can be included in a residential site plan, a separate landscaping plan is not required. The requirements include but are not limited to:
a. One canopy tree is required for every 1,000sqft of new gross floor area in the development project (0-1,000sqft – 1 tree, 1,001-2,000sqft – 2 trees). The current proposal would require two canopy trees.
b. 5 feet of vegetative groundcover along the length of the street frontage, minus the curb cut width. For this lot, approximately 200sqft of vegetative groundcover will be required in the front street setback. Show this area on the site plan.
c. Landscaping requirements may be met by existing landscape features on the site, but the existing landscaping must be indicated on the site plan. Please indicate existing on-site landscaping on the site plan.
d. See Ordinance 12219 for the full list of landscaping standards.

The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code

For questions regarding Zoning comments, please contact me at: Erick.Bieber@tucsonaz.gov
03/06/2026 PDSD Application Completeness Express REVIEW COMPLETED