Permit Number: TC-RES-0325-01617
Parcel: 113072790

Review Status: Requires Resubmit

Review Details: RESIDENTIAL NEW DWELLING v.2

Permit Number - TC-RES-0325-01617
Review Name: RESIDENTIAL NEW DWELLING v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
05/08/2025 Site Zoning - Standard APPROVED
05/09/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
05/05/2025 Residential Building - Standard REQUIRES RESUBMIT TC-RES-0325-01617
PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide a separate Comment Response Letter when submitting updated plans. Facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval.

PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2018 IRC code compliance.

Provide a response letter addressing each comment with location of change on the plans. Submit separate letter and plan set files.

PLANS:

1. Show the bedroom window sizes in compliance with R310 providing egress. The 3040DH does not provide a clear 24” opening height.

SECTIONS - DETAILS:

1. Clarify the placement of ceiling/roof insulation for determining the need for attic ventilation, R806. Attic space outside of the thermal barrier requires a ventilation calculation for showing the attic vent opening size using 1 to 150 of attic area in compliance with R806.2 if using the gable vent shown at the East Elevation on sheet A105. Or an unvented roof assembly requires an air-impermeable rigid insulation material with a minimum R-5 value applied correctly to either side of the roof sheathing if placing the insulation as shown on A104, R806.5. Provide a consist ceiling/roof insulation placement.

MECHANICAL PLANS:

1. Show the (dryer) exhaust with not less than a 4” VTR diameter, Table M1504.2.

If you have any questions, please contact:
PDSD-Residential@tucsonaz.gov
City of Tucson Residential Plan Review

Submit a corrected plan set at https://www.tucsonaz.gov/Departments/Planning-Development-Services
----------------------
05/09/2025 Site Engineering - Standard REQUIRES RESUBMIT TC-RES-0325-01617
2812 N MOUNTAIN AV

Site engineering comments are as follows:
1. This project lies within a recognized floodplain and requires a Floodplain Use Permit (FUP).

Please start a new FUP at our permit application web page:
https://tdc-online.tucsonaz.gov/#/home

NOTE: A cost estimate of materials and labor from your contractor in the form of a pdf attachment will be required to complete the FUP application. Please have separate lines for cost of materials, and cost of labor. Thank you.

Ryan Insalaco
Engineering Associate
04/09/2025 PDSD Application Completeness Express REVIEW COMPLETED