Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: TC-RES-0325-01596
Parcel: 14017305C

Address:
4937 S CHERRY AV

Review Status: Requires Resubmit

Review Details: RESIDENTIAL NEW DWELLING v.2

Permit Number - TC-RES-0325-01596
Review Name: RESIDENTIAL NEW DWELLING v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
07/02/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
06/23/2025 Residential Building - Standard REQUIRES RESUBMIT TC-RES-0325-01596 2nd
PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide a separate Comment Response Letter when submitting updated plans. Facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval.

PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2018 IRC code compliance. The plans require sufficient detail for demonstrating minimum building code compliance for passing all progress inspections.

Remove the 2012 IRC and Santa Cruze County note from sheet A-3.0 and A-4.0. Use appropriate references on all sheets.

Provide a response letter addressing each comment with location of change on the plans. Submit separate letter and plan set files.

PLANS:

1. Clarify the area of proposed addition, R106.1.1. The area shown on sheet A-2.0 shows 303 SF of dwelling and storage space for the total addition after removal of an undefined room on sheet D-1.0.
2. Show one-hour fire-resistive framed construction in compliance with IBC Table 721.1(2) for the addition wall located at the (neighboring) property line, R302.1. Detail #1 on sheet A-1.0 is not compliant for fire spread control.
3. Existing bedrooms with altered windows require code compliance for egress, R310. Replace the 3030XO Master Bedroom window with a door or window providing a minimum 5 SF openings and minimum 20” clear width. A 3030-casement style or larger opening is required.
4. Clarify if the 2”x 8” truss is a manufacturer’s engineered truss system or a 2”x 8” rafter with ceiling joist, R106.1. A truss may not be spliced without an engineer’s design and seal. The details on sheet A-3.0 shows truss alterations without a required engineer’s stamped plans.

SECTIONS - DETAILS:

1. Clarify the placement of ceiling/roof insulation for determining the need for attic ventilation, R806. Attic space outside of the thermal barrier requires a ventilation calculation for showing the attic vent opening size using 1 to 150 of attic area in compliance with R806.2 or an unvented roof assembly requires an air-impermeable rigid insulation material with a minimum R-5 value applied correctly to either side of the roof sheathing, R806.5. Identify the ventilation requirements and insulation types for complying with the condensation control issues.

If you have any questions, please contact:
PDSD-Residential@tucsonaz.gov
City of Tucson Residential Plan Review

Submit a corrected plan set at https://www.tucsonaz.gov/Departments/Planning-Development-Services
----------------------
07/02/2025 Site Zoning - Standard REQUIRES RESUBMIT PDSD TRANSMITTAL

FROM: Jeffrey W. Cassidy, Planner
Planning & Development Services Department – Zoning Review Section

PROJECT: TC-RES-0325-01596 – Residential Building – As-Built Modification and Enclosure
4937 S Cherry Av Tucson, AZ 85706 (R-2 Zoning)
Building Plan Review – 2nd Review

TRANSMITTAL DATE: July 2, 2025

This site is in the R-2 zone (UDC 4.7.9). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.6, .9, & .10.

Plan review for the above referenced as built modification and enclosure and has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment updates; revisions are processed if changes occur after the permit is issued.

RESUBMITTAL OF THE FOLLOWING IS REQUIRED:
Correct the following plot (site) plan and elevation sheets, as noted in the comments below, along with a detailed response letter indicating responses to the review comments.

PLANS:

1. COMMENT: See Previous Comment #1/1st Review. Per the UDC Table 6.-2.A and UDC Article 6.4.5.C.1, complete the side and rear yard setbacks (6’ or 2/3(h), whichever is greater).

2. COMMENT: See Previous Comment #2/1st Review: Label the 30’ sidewalk/sewer/water/yard/landscape easement along with the recording information on the plan. For reference, see https://onbase.pima.gov/publicaccess/DS_NextGen_Single/etc/cq/results.html?cqid=240&OBKey__552_1=20033

3. COMMENT: See Previous Comment #3/1st Review: Provide recording information. For reference, see https://onbase.pima.gov/publicaccess/DS_NextGen_Single/etc/cq/results.html?cqid=240&OBKey__552_1=20033

4. COMMENT: See Previous Comment #4/1st Review: Provide recording information. For reference, see https://onbase.pima.gov/publicaccess/DS_NextGen_Single/etc/cq/results.html?cqid=240&OBKey__552_1=20033

5. COMMENT: See Previous Comment #6/1st Review: Drawing footprint doesn’t match the aerial (aerial depicts structure touching the east property line within the parking easement) Update plan drawing accordingly.

6. COMMENT: Additional comments may be forthcoming on the next review based on responses to Zoning and other the PDSD reviewer comments.

Please contact the zoning reviewer if you have any zoning questions:

Jeffrey W Cassidy
jeffrey.cassidy@tucsonaz.gov
City of Tucson Site Zoning and Planning Reviewer

Feel free to visit our counter of the Public Works building and ask for me at 201 N Stone Ave Tucson, AZ 85701, Monday thru Thursday, 8am-12pm, for an in-person consultation to go over my comments if this is more helpful.

Submit a corrected plan set at https://www.tucsonaz.gov/Departments/Planning-Development-Services
06/03/2025 PDSD Application Completeness Express REVIEW COMPLETED Project description does not outline corrective measures to violations in CE-VIO0325-01002.