Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-RES-0226-01017
Parcel: 111082500

Review Status: Requires Resubmit

Review Details: RESIDENTIAL ADD/ALT v.1

Permit Number - TC-RES-0226-01017
Review Name: RESIDENTIAL ADD/ALT v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
03/02/2026 Bldg Permits - Post Review Express PENDING ASSIGNMENT
03/02/2026 Addressing Validation REQUIRES RESUBMIT For questions: PDSD-Permits@tucsonaz.gov.

Please include full property address on site plan and resubmit after other reviews are complete.

Step-by-Step instructions on how to resubmit: https://www.tucsonaz.gov/files/sharedassets/public/pdsd/documents/tdc-faq/new-pdfs/revisions-and-resubmittals.pdf
03/02/2026 Light Residential Building Review (OIP) - Standard REQUIRES RESUBMIT Please show or describe how Whole home surge protection will be installed in the panel and re submit. Code references from the 2024 IRC & 2023 NEC below.

If you have any questions, you can reach me at: jorge.ruiz@tucsonaz.gov

E3606.5 Surge protection: all services supplying dwelling units shall be provided with a surge-protective device (SPD) installed in accordance with Sections E3606.5.1 through E3606.5.3.

E3606.5.1 Location: the SPD shall be an integral part of the service equipment or shall be located immediately adjacent, if not located at each next-level distribution equipment downstream toward the load.

E3606.5.2 Type: the SPD shall be a Type 1 or Type 2 SPD.

E3606.5.3 Replacement: Where service equipment is replaced, all of the requirements of this section shall apply.



2023 NEC 230.67 mandates whole-house surge protection (SPD) for services supplying dwelling units, dormitories, hotel/motel guest rooms, and patient rooms in nursing homes, requiring a Type 1 or Type 2 SPD, often built-in or next to the service, with a minimum 10kA nominal discharge current rating, and also applies to service replacement, expanding on the 2020 code's requirement for just dwelling units.
03/02/2026 PDSD Application Completeness Express REVIEW COMPLETED