Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.9
Permit Number - TC-RES-0223-02907
Review Name: RESIDENTIAL NEW DWELLING v.9
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/08/2024 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 12/27/2023 | Residential Building | REQUIRES RESUBMIT | TC-RES-0223-02907 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment updates; revisions are processed if changes occur after the permit is issued. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. GENERAL REQUIREMENTS: Separate the submitted pages with construction plans and support documents in different files. Clarify the plans showing proposed construction and the existing which is the last permitted and inspected construction. SITE PLAN: 1. Identify the utility lines requiring upgrade or replacement, R106.1.1. The undersized ½” water supply line requires a minimum ¾” size between the meter and water heater, P2903.7. PLANS: 1. Show sleeping rooms with R310 compliant egress. The notes on sheet #4 list two loft windows but the plan shows one. Place the compliant window size at the window location on the plan. SECTIONS - DETAILS: 1. Show stairway tread and run dimensions in compliance with AQ104.2.1. ELECTRICAL PLANS: 1. Provide an Electrical Plan for the loft, E3404.12. If you have any questions, please contact: PDSD-Residential@tucsonaz.gov City of Tucson Residential Plan Review Submit a corrected plan set at https://www.tucsonaz.gov/pdsd |
||
| 01/08/2024 | Site Zoning | REQUIRES RESUBMIT | Nathan Herrera PDSD Zoning Review Section PROJECT: TC-RES-0223-02907 / ADU Plot Plan Review (5th Review) 4018 E 3rd St / R-1 TRANSMITTAL DATE: 1/08/2024 COMMENT: It appears that the most recent submittal did not contain the full plan set. The setback dimensions on the plan set need to show the approved DDO setback reduction of 7 feet from the west lot line and 7 feet from the south lot line, and contain information found on the residential plot plan example, found at: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/residential_plot_plan_requirements.pdf The construction plan set uploaded on 7/21/2023 is an acceptable example, as long as those plans reflect the DDO approval. Resubmittal instructions: https://www.tucsonaz.gov/files/sharedassets/public/pdsd/documents/tdc-faq/new-pdfs/revisions-and-resubmittals.pdf For questions regarding Zoning comments, please contact me at: Nathan.Herrera@tucsonaz.gov |
||
| 12/13/2023 | PDSD Application Completeness Express | REVIEW COMPLETED |