Permit Number: TC-MDP-1125-00731
Parcel: 13817031B

Review Status: Requires Resubmit

Review Details: SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.1

Permit Number - TC-MDP-1125-00731
Review Name: SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
01/08/2026 Fire New Construction NOT REQUIRED
01/20/2026 Bldg Permits - Post Review Express PENDING ASSIGNMENT
01/07/2026 Addressing Validation REQUIRES RESUBMIT The permit shows to be for a SFR & ADU. The location and plan do not have units attached to the address 374 E CORONA RD. Please contact Pima County Addressing at addressing@pima.gov or 520-724-9512 to verify and add the units. Please resubmit all permit documents listing the new assigned units along with an address change request to add the units to this permit. For questions: Building_Official@tucsonaz.gov
01/14/2026 Residential Building REQUIRES RESUBMIT Requires resubmit.

Please provide full construction drawings. Submitted drawings are cropped.
01/20/2026 Residential Engineering REQUIRES RESUBMIT Permit: TC-MDP-1125-00731
Location: 374 E CORONA RD
Review Date: 1/20/2026

Residential Engineering Comments:
1. The accessible route is provided, please show the dimensions of the accessible route as well as material of “parking spot” shown on overall site plan.
2. Clarify how the accessible route reaches the sidewalk located in the Right-of-Way. In the individual site plan it appears that the sidewalks on the site and in the ROW connect. When resubmitting the overall site plan, please show the accessible route connecting to the permit in the ROW.

If you have any questions or concerns, please contact Dylan Molina.
Dylan.Molina@tucsonaz.gov
01/14/2026 Residential Zoning REQUIRES RESUBMIT PDSD TRANSMITTAL

FROM: Roxanne Johnston
Planner

PROJECT: TC-MDP-1125-00731
374 E Corona Rd., Tucson, AZ 85756
Model SFR with ADU (1st Review)

TRANSMITTAL DATE: 1/14/2026

This site is located within the R-2 Zone (UDC 4.7.9). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.6, .9, & .10.

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Correct plans, as noted in the comments below, along with a response letter indicating how all Site Zoning comments were addressed.

1. Twp site plans were submitted, what appears to be a landscape plan and another that does not show the southern area of the lot. Both site plans are missing information required for a Site Zoning Review and appears to be a landscape plan only. Please use the following link to find a site/plot plan example and the required items for your next submittal:
https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Plan-Examples/Plot-Plan-Example Until this site plan is provided, Site Zoning will not be able to process your application. Please note that each duplex/ADU combo will require the its own site plan. Some of the required information to be noted directly on the site plan includes:

a. Owner name & address
b. Lot address: 374 E Corona Rd.
c. Parcel number: (see Addressing Validation comment from 01/07/2026)
d. Legal lot description Golden Dawn Farms PTN E 125.40’ Lot 43
e. Square footage of each unit
f. Square footage of the vehicle use area
g. Lot coverage – all enclosed structure square footage plus vehicle use area square footage divided by the square footage of the lot – should be presented as a percentage.
h. North arrow
i. Engineer scale (e.g. 1” = 20’)
j. Full lot dimensions
k. The correct Lot number corresponding to the correct address. The materials submitted (the site plan that was cut off) indicates that this was to be a review for Lot 2 addressed as 380 E Corona Rd, rather than Lot 4, which is addressed as 374 E Corona Rd.

2. Additional comments may be forthcoming depending on responses to zoning review comments and plans submitted for the next review.

If you have any questions about this transmittal, please contact Roxanne Johnston at roxanne.johnston@tucsonaz.gov .
01/07/2026 PDSD Application Completeness Express REVIEW COMPLETED
01/07/2026 ROW Engineering Review REVIEW COMPLETED DTM Review Comments -
1. Driveway (PAG SD 206) Max. width for residential driveway is 20’ or 30' Shared Driveway
2.Sidewalk (PAG SD 200) 5’ for Local roadways.
3.Road Type: Local
4.Current Road Conditions on E Corona Rd - Under Pavement Moratorium.
*Unused existing curb cuts shall be closed.
All work within City Right of Way to require separate and individual ROW permit requests per each scope of work to be performed.
01/13/2026 TW New Development Review Fast REVIEW COMPLETED Tucson Water New Area Development has no objections and no additional comments for this project.

If any new water meter(s) and/or irrigation service(s) are needed for this project, please contact Tucson Water’s New Services Section.