Permit Review Detail
Review Status: Requires Resubmit
Review Details: SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.1
Permit Number - TC-MDP-1123-01835
Review Name: SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/19/2024 | Fire New Construction | NOT REQUIRED | |||
| 10/02/2024 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 09/30/2024 | Residential Building | REQUIRES RESUBMIT | Permit Review TC-MDP-1123-01835 (1603 S VAN BUREN AV TUCSON, AZ 85711) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2018 International Residential Code (IRC), 2018 International Plumbing Code (IPC) 1. The building sewer line, for units 3 and 4, is shown crossing into the neighboring parcel. There is no record of a Pima County sewer line in this location. You cannot cross property boundaries to share a sewer connection. 2018 IPC 701.3. 2. Provide elevation measurements for Next Upstream Manhole cover and Finished Floor Elevation. Provide Backwater valve protection as/if required. 3. Backwater valve protection: https://www.tucsonaz.gov/files/sharedassets/public/pdsd/documents/building-code/2018_-_irc_amendments.pdf Section P3008.1 Where required. Where the finish floor elevation is less than 12 inches above the elevation of the next upstream manhole cover in the sewer, a backwater valve shall be installed in the building drain or branch of the building drain serving that floor. Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov |
||
| 09/23/2024 | ROW Engineering Review | REQUIRES RESUBMIT | Site plan: Show existing and proposed Right-of-Way features. Provide distances and dimensions for the following: 1. Driveway (PAG SD 206) Max. width for residential driveway is 20’ 2.Sidewalk (PAG SD 200) 5’ for Local roadways. 3.Road Type: Local, Show setback *Unused existing curb cuts shall be closed. |
||
| 10/01/2024 | Site Engineering | REQUIRES RESUBMIT | 1. A separate building permit is required for each building and the plans must be specific for the building. Mike Ortiz michael.ortiz@tucsonaz.gov |
||
| 10/02/2024 | Site Zoning | REQUIRES RESUBMIT | FROM: PDSD Zoning Review Section PROJECT: TC-MDP-1123-01835 1603 S VAN BUREN AV. – R-2 Multifamily (1st Review) TRANSMITTAL DATE: October 2, 2024 COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This site is located in the R-2 zone (UDC 4.7.9) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.6, .9, & .10. 1. The proposed multifamily project requires a Development Package (DP) meeting the requirements of Administrative Manual (AM) 2-06 must be submitted and approved prior to approval of this building plan. The Administrative Manual can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes-and-Plans/Zoning-Code#section-1. This DP is a separate submittal form the building plans. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
||
| 09/18/2024 | PDSD Application Completeness Express | REVIEW COMPLETED |