Permit Review Detail
Review Status: Requires Resubmit
Review Details: SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.3
Permit Number - TC-MDP-1025-00683
Review Name: SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.3
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 02/09/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 02/09/2026 | Residential Engineering | REQUIRES RESUBMIT | Permit: TC-MDP-1025-00683 Location: 1225 S HERNDON AV Review Date: 2/9/2026 A Comment Response letter is required. Please address all reviewer’s comments in a separate document with all required documents for resubmittal. Residential Engineering Comments: 1. The permit number on the site plan must match the master model permit (TC-MDP-0325-00203, not TC-MDP-1025-00683). 2. Per comment response letter, it was requested that the accessible route be 48” (4-FT) not 36” as mentioned and shown. Please correct the dimensions. 3. Due to site constraints, it is advised to request review change to Middle Housing UDC Code Amendment which has gone into effect as of January 1, 2026. The site plan must conform to all requirements. If you have any questions or concerns, please contact Dylan Molina. Dylan.Molina@tucsonaz.gov |
||
| 02/04/2026 | Residential Zoning | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Jeffrey W. Cassidy, Planner Planning & Development Services Department – Current Zoning Review Section PROJECT: TC-MDP-1025-00683 –Residential Building – SFR (MODEL MASTER PLAN TC-MDP-0325-00203) 1225 S HERNDON AV TUCSON, AZ 85713 (R-3 Zoning) Site Plan Review – 3rd Review TRANSMITTAL DATE: February 04, 2026 This site is in the R-3 Residence Zone (UDC 4.7.12). A single-family residence is permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.6. Plan review for the above referenced single-family residence has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment updates; revisions are processed if changes occur after the permit is issued. 1. COMMENT: Refer to previous Residential Engineering reviewer comments 4 (Review #2) regarding the required accessible route to be a minimum of 4’-0” wide. Currently, the drawing is indicating a 3’-0” width. 2. COMMENT: Change the Model Plan currently labeled as TD-MDP-1025-00683 to the desired TC-MDP-0325-00203 on the site plan. 3. COMMENT: Add the missing 57.13’ property line dimension (separating Lot 1 from Lot 2). 4. COMMENT: Additional comments may be forthcoming on the next review based on responses to Zoning and other PDSD reviewer comments. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: 1. Corrected building permit 2. Provide a detailed response letter with your submittal that clearly shows how you have addressed all Zoning comments. 3. Resubmit ALL documents associated with this permit To resubmit visit Tucson Development Center at https://tdc-online.tucsonaz.gov/#/home Instructions for resubmittal - https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/tdc-faq/old-pdfs/double-old/resubmittals.pdf If you have any questions about this transmittal, please contact jeffrey.cassidy@tucsonaz.gov The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code |
||
| 01/26/2026 | PDSD Application Completeness Express | REVIEW COMPLETED | |||
| 02/03/2026 | ROW Engineering Review | REVIEW COMPLETED | DTM Review Comments - Separate or Individual permits to be required per Scope of Work Performed |