Permit Review Detail
Review Status: Requires Resubmit
Review Details: SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.1
Permit Number - TC-MDP-1025-00643
Review Name: SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/07/2025 | Fire New Construction | NOT REQUIRED | |||
| 11/04/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 10/21/2025 | Residential Building | REQUIRES RESUBMIT | ACTIVITY NO. TC-MDP-1025-00643 ADDRESS/PARCEL: (2527 S CAMPBELL AV TUCSON, AZ 85713) The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review. COMMENTS: 1. Please show the RIM elevation of the nearest upstream manhole on the site plan. (P3008.1, City of Tucson Amendments) a. Will be used to confirm whether a backwater valve is required 2. Please show where the electrical service lines enter the building and the location of the electrical panel |
||
| 10/07/2025 | Residential Engineering | REQUIRES RESUBMIT | Permit: TC-MDP-1025-00643 Location: 2527 S CAMPBELL AV Review Date: 10/7/2025 Site Engineering Comments: 1. The FFE shows a typo of 7482.5. Revise Accordingly. 2. For the Easternmost parking spaces, show compliance with the required Back-up spur requirements. UDC 7.4.6.F.4 3. Show how the sites are to function separate through a fence/wall. 4. Plans state Lot 6, but based on the address this would appear to be lot 3 of Campbell Estates. 5. On the plans, it shows 2152 SF for the Duplex, but each unit is 1079 SF which totals 2158, Revise accordingly. If you have any questions or concerns, please contact Marco Contreras Marco.contreras@tucsonaz.gov |
||
| 10/22/2025 | Residential Zoning | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Erick Bieber Planning & Development Services Department – Zoning Review Section PROJECT: TC-MDP-1025-00643 2527 S Campbell Ave, Tucson, AZ 85713 Model Building Permit (1st Review) TRANSMITTAL DATE: October 22nd, 2025 This site is located in the C-1 zone (UDC 4.7.20). A duplex is a permitted use in this zone. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Correct plans, as noted in the comments below, along with a response letter indicating how all Site Zoning comments were addressed. 1. (Comment) Lots connected through shared use of a parking lot are viewed as one site. As the combined site contains 3 or more units, a Development Package (DP) will be required. 2. (Comment) A fence/wall is required to demonstrate that the sites are separate. 3. (Comment) Submitted plans do not match the supplemental site plan provided in TD-DIV-0424-00034. 4. (Comment) Indicate all lot dimensions. 5. (Comment) Clarify the inconsistent lot numbering indicated throughout the plan. The legal description and site plan indicate the site is Lot 6, while the final plat indicates that the site is Lot 3. 6. (Comment) The square footage of the duplex indicated on the site plan does not match the building area calculations listed on the submission or in the model plan. The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code For questions regarding Zoning comments, please contact me at: Erick.Bieber@tucsonaz.gov |
||
| 11/04/2025 | ROW Engineering Review | REQUIRES RESUBMIT | 1. Show 24’ curb cut with 4’ transitions 2. Show existing “roll” curb. 3. New 24’ driveway per PAG SD should be concrete from roll curb to back of sidewalk, new sidewalk area should be 6’ wide. 4. Show 3’ backup spur for onsite turnaround area. DTM Comment file has been added to attachments |
||
| 10/07/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |