Permit Number: TC-MDP-0925-00548
Parcel: 130057070

Review Status: Requires Resubmit

Review Details: SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.1

Permit Number - TC-MDP-0925-00548
Review Name: SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
10/07/2025 Fire New Construction NOT REQUIRED
11/04/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
10/20/2025 Residential Building REQUIRES RESUBMIT ACTIVITY NO. TC-MDP-0925-00548
ADDRESS/PARCEL: (2447 S CAMPBELL AV TUCSON, AZ 85713)
The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review.
COMMENTS:
1. Please show the RIM elevation of the nearest upstream manhole on the site plan. (P3008.1, City of Tucson Amendments)
a. Will be used to confirm whether a backwater valve is required
2. Please show where the electrical service lines enter the building and the location of the electrical panel.
10/07/2025 Residential Engineering REQUIRES RESUBMIT Permit: TC-MDP-0925-00548
Location: 2447 S CAMPBELL AV
Review Date: 10/7/2025
Site Engineering Comments:
1. The final Plat for Campbell Estates shows lot 7 to be 9,558 SF, revise plans accordingly.
2. Provide a call out for the 15’ utility easement.
3. The FFE shows a typo of 7479.7. Revise Accordingly.
4. The plans show varying square footage compared to what is shown in TC-MDP-1223-01917. Revise the square footage and calculations.
5. The property line measurements do not align with what the final plat shows, revise the distances presented.
6. For the southern most parking space, show compliance with the required Back-up spur requirements. UDC 7.4.6.F.4
7. Show that vertical separate exists along the southern portion of the parking area to contain the driving area to the parking lot.
8. A shared access driveway detail is shown but does not appear to apply to this site layout, please provide explanation to this.
9. Show how the sites are to function separate through a fence/wall.
If you have any questions or concerns, please contact
Marco Contreras
Marco.contreras@tucsonaz.gov
10/22/2025 Residential Zoning REQUIRES RESUBMIT PDSD TRANSMITTAL

FROM: Erick Bieber
Planning & Development Services Department – Zoning Review Section

PROJECT: TC-MDP-0925-00548
2447 S Campbell Ave, Tucson, AZ 85713
Model Building Permit (1st Review)

TRANSMITTAL DATE: October 22nd, 2025

This site is located in the R-2 zone (UDC 4.7.9). A duplex is a permitted use in this zone with the following use specific standards: 4.9.7.B.6, .9 & .10.

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Correct plans, as noted in the comments below, along with a response letter indicating how all Site Zoning comments were addressed.

1. (Comment) Correct and indicate all lot line dimensions.

2. (Comment) Shared access driveway easement detail inset shows the incorrect site.

3. (Comment) Clarify the inconsistent lot numbering indicated throughout the plan. The legal description indicates the site is Lot 2, while the site plan and final plat indicate the site is Lot 7.

4. (Comment) Correct zoning under Zoning Information. The site is zoned R-2.

5. (Comment) Correct address under Zoning Information.

6. (Comment) The building area calculations do not match the duplex information noted on the site plan or any of the models indicated in the model building plan.

7. (Comment) The lot area calculations do not match the lot dimensions or what is indicated on the final plat.


The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code


For questions regarding Zoning comments, please contact me at: Erick.Bieber@tucsonaz.gov
11/04/2025 ROW Engineering Review REQUIRES RESUBMIT 1. Driveway should be 24'
2 Rearrange onsite parking for consistency with other parcels, provide 3' backup spur.
DTM Comment File has been added to attachments
10/06/2025 PDSD Application Completeness Express REVIEW COMPLETED