Permit Number: TC-MDP-0923-01566
Parcel: 13216611B

Review Status: Requires Resubmit

Review Details: SITE FROM MODEL PERMIT - SUBDIVISION v.3

Permit Number - TC-MDP-0923-01566
Review Name: SITE FROM MODEL PERMIT - SUBDIVISION v.3
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
01/02/2024 Residential Building APPROVED
01/18/2024 Bldg Permits - Post Review Express PENDING ASSIGNMENT
01/04/2024 Site Engineering REQUIRES RESUBMIT 1. Indicate on the plans that the finished floor elevation is above the regulatory flood elevation as provided in comments on the floodplain use permit. The FFE must be a foot above the base flood elevation of 2496.86 NAVD88. The FFE must be 2497.86 feet NAVD88 or higher.

Lianne Evans
lianne.evans@tucsonaz.gov
01/02/2024 Site Zoning REQUIRES RESUBMIT FROM: PDSD Zoning Review Section

PROJECT: TC-MDP-0923-01566
4558 S. Fremont Av. - C-1
New Duplex (3rd Review)

TRANSMITTAL DATE: January 2nd, 2024

Provided a detail comment response letter with your submittal that clearly shows how you have addressed all comments with your next submittal.

This site is located in the C-1 zone (UDC 4.7.20). a duplex is a permitted use in this zone (Table 4.8-4).

1. Perimeter yard setbacks are based on a measurement from design grade to the highest point of the exterior wall UDC Article 6.4.5.B & Figure 6.4.5-A. Per UDC Table 6.3-4 the required perimeter yard setback to the north, south, west property line is 10' or ¾(H), (H) = Height of the proposed exterior building wall, the greater of the two dimensions applies. Based on a wall height of 9’-0” the required perimeter yard setback to the north property line is 10’-0”, proposed setback is 6’-0”.

Zoning acknowledges a Design Development Option (DDO) has been submitted. Zoning cannot approve of this permit until the DDO process is completed and approved If you have questions about the DDO application or process please contact Wyatt Berger at Wyatt.Berger@tucsonaz.gov or Georgia Pennington at Georgia.Pennington@tucsonaz.gov.



If you have any questions about this transmittal, please contact Nathan.Herrera@tucsonaz.gov.
01/18/2024 Zoning Modifications - DDO REQUIRES RESUBMIT DDO-24-05 is currently in progress. If the DDO is approved, provide a copy of your decision notice AFTER the notice of intent to appeal period has passed, in addition to a revised plan set and comment response letter.

Contact me at Wyatt.Berger@tucsonaz.gov or at 520-837-4951 should you have questions about the DDO process.
12/29/2023 PDSD Application Completeness Express REVIEW COMPLETED