Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-MDP-0824-00980
Parcel: 116231980

Review Status: Requires Resubmit

Review Details: SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.1

Permit Number - TC-MDP-0824-00980
Review Name: SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
09/24/2024 Residential Building APPROVED
09/26/2024 Site Engineering APPROVED
09/12/2024 Fire New Construction NOT REQUIRED
09/26/2024 Bldg Permits - Post Review Express PENDING ASSIGNMENT
09/25/2024 Site Zoning REQUIRES RESUBMIT FROM: PDSD Zoning Review Section

PROJECT: TC-MDP-0824-00980
905 S KROEGER LN Unit: 2 – R-2
New Accessory Dwelling Unit (ADU) (1st Re

TRANSMITTAL DATE: September 25, 2024

COMMENTS: Resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

This site is located in the R-2 zone (UDC 4.7.9). A single family dwelling with an accessory dwelling unit (ADU) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.6, 8, & 9 and 6.6.3.

1. As the proposed ADU walls are parallel to the property lines UDC Article B.5 apply. Provide perimeter yard setback dimensions for the midpoint of the ADU wall to the north, south and east property line. Also provide setback dimensions from 1) the northeast corner of the ADU to the east property line, 2) from the north west corner of the ADU to the north property line, and 3) from the southeast corner of the ADU to the south property line.

2. It does not appear that the wall heights provided on the site plan are correct. Perimeter yard setbacks are based on a wall height measurement from design grade to the highest point of the exterior wall UDC Article 6.4.5.B & Figure 6.4.5-A. Model plan TC-MDP-0224-00265 sheet A-03 Ext. Elevations + Schedules, none of the EL heights are from design grade therefore 6” will be added to the provided elevations heights to determine required perimeter yard setback heights. Also, on 3 Elevation C there is no height dimension provide to the highest point of the wall. This dimension should be from design grade to where the wall meets the eave at the low end or the roof.

The following comments are based on the wall heights provided on the site plan plus 6” to design grade.

1. Northeast corner of the ADU to the north property line - Based on a wall height of 11’-6” the required perimeter yard setback to the north property line is 7‘-8”, proposed is 3’-0”.

2. Northwest corner of the ADU to the north property line - Based on a wall height of 13’-6” the required perimeter yard setback to the north property line is 9‘-0”, proposed dimension was not provided.

3. Northeast corner of the ADU to the east propery line - Based on a wall height of 11’-6” the required perimeter yard setback to the east property line is 7‘-8”, proposed dimension was not provided.

4. Southeast corner of the ADU to the east property line - Based on a wall height of 11’-6” the required perimeter yard setback to the east property line is 7‘-8”, proposed is 5’-0”.

5. Southeast corner of the ADU to the south property line - Based on a wall height of 13’-6” the required perimeter yard setback to the south property line is 9‘-0”, proposed dimension was not provided.

6. Southwest corner of the ADU to the south property line - Based on a wall height of 13’-6” the required perimeter yard setback to the south property line is 9‘-0”, proposed is 3’-8”.

The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code.

If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov.
09/25/2024 Zoning Modifications - DDO REQUIRES RESUBMIT Per Tucson Unified Development Code (UDC) 6.4.5.B.5, where an unbroken section of a wall or a building is not parallel with the lot line, the required perimeter yard setback may be applied to the average width; however, such perimeter yard setback shall not be narrower at any point than half the required width, nor narrower at any point than three feet. See UDC Figure 6.4.5-A for an illustration of this standard.

As noted in the Site Zoning comments, label the distance from the northwest corner of the ADU to the north lot line, the distance from the northeast corner of the ADU to the east lot line, and the distance from the southeast corner of the ADU to the south lot line. A Design Development Option (DDO) will not be required if the average setbacks meet the minimum requirements of the above standard.

If a DDO is still required, provide the average setbacks on the "Project Description and Applicant's DDO Request" page rather than the setbacks measured from the closest corners of the ADU to the lot lines.

Contact me at Wyatt.Berger@tucsonaz.gov or 520-837-4951 if you have questions about the above comments.
09/12/2024 PDSD Application Completeness Express REVIEW COMPLETED
09/13/2024 ROW Engineering Review REVIEW COMPLETED No Comments on proposed work from ROW.