Permit Number: TC-MDP-0824-00892
Parcel: 11806113C

Address:
1931 W KING AV

Review Status: Requires Resubmit

Review Details: SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.3

Permit Number - TC-MDP-0824-00892
Review Name: SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.3
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
12/23/2024 Site Landscape NOT REQUIRED
01/06/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
12/26/2024 Site Engineering REQUIRES RESUBMIT TC-MDP-0824-00892
1931 W KING AV

Site engineering comments are as follows:
1. Please refer to UDC 5.2.7 and TSM 9 for HDZ calculations and applicable exceptions therein.
2. Hillside development also requires a separate grading permit.
Please visit: https://tdc-online.tucsonaz.gov/#/home
Ryan Insalaco – ryan.insalaco@tucsonaz.gov
01/06/2025 Site Zoning REQUIRES RESUBMIT FROM: PDSD Zoning Review Section

PROJECT: TC-MDP-0824-00892
1931 W KING AV . – R-1
New SFR (2nd Review)

TRANSMITTAL DATE: January 6, 2025

Provided a detail comment response letter with your submittal that clearly shows how you have addressed all comments with your next submittal.

This site is located in the R-1 zone (UDC 4.7.8). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5 – 9.

1. This comment was not fully addressed. There was no dimension provided from the face of curb to the property line. Review Construction Plan I-78-035 found at: https://maps-and-records.tucsonaz.gov/construction-plans/details/I-78-035, and provide a dimension from the centerline of King Ave. to the face of curb and from face of curb to the north property line.

2. This comment was not addressed. There was not lot coverage calculation provided on the plan. The provided lot coverage calculation is not correct. Review UDC Article 6.4.3 and the example shown on the Residential Plot Plan Requirements found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Building-Safety/Plan-Examples/Plot-Plan-Example, and provide a correct lot coverage calculation.

The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code.

If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov.
12/12/2024 PDSD Application Completeness Express REVIEW COMPLETED
12/16/2024 ROW Engineering Review REVIEW COMPLETED