Permit Number: TC-MDP-0824-00892
Parcel: 11806113C

Address:
1931 W KING AV

Review Status: Requires Resubmit

Review Details: SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.2

Permit Number - TC-MDP-0824-00892
Review Name: SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
08/27/2024 Residential Building APPROVED
08/28/2024 Fire New Construction NOT REQUIRED
09/11/2024 Bldg Permits - Post Review Express PENDING ASSIGNMENT
09/10/2024 ROW Engineering Review REQUIRES RESUBMIT Show existing and proposed Right-of-Way features. Provide distances and dimensions for the following:
1. Driveway, proposed 12' driveway location may need to be adjusted to match existing driveway.
09/11/2024 Site Engineering REQUIRES RESUBMIT Site Engineering Comments for TC-MDP-0824-00892 are as follows:
1. This project requires a Development Package that includes a grading plan and NPPO. Include the area of disturbance and cut/fill quantities on the grading plan.
2. Provide Average Cross Slope (ACS) calculations to justify the extent of proposed grading. See UDC 5.2

Ryan Insalaco
Engineering Associate
City of Tucson
Planning & Development Services Department
Email: ryan.insalaco@tucsonaz.gov
09/10/2024 Site Zoning REQUIRES RESUBMIT FROM: PDSD Zoning Review Section

PROJECT: TC-MDP-0824-00892
1931 W KING AV . – R-1
New SFR (1st Review)

TRANSMITTAL DATE: September 10, 2024

Provided a detail comment response letter with your submittal that clearly shows how you have addressed all comments with your next submittal.

This site is located in the R-1 zone (UDC 4.7.8). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5 – 9.

1. The provided legal description is not correct and should be “HIRAM BANKS ACRES W100' N150' W2 LOT 49”.

2. The property dimensions are not correct. Review the Assessor’s Record Map found at: https://www.asr.pima.gov/ParcelData/Map/Arm/MP06/06093_01.pdf, and provide the correct property dimensions.

3. Review Construction Plan I-78-035 found at: https://maps-and-records.tucsonaz.gov/construction-plans/details/I-78-035, and provide a dimension from the centerline of King Ave. to the face of curb and from face of curb to the north property line.

4. The “25’ SETBACK” shown on the plan is not correct. Review UDC Article 6.4.5.C.1.a and provide the correct setback.

5. The “10’ SETBACK”, side, & and the “30’ SETBACK”, rear, shown on the plan are not correct. Review UDC Table 6.3-2.A and provide the correct setback.

6. The provided lot coverage calculation is not correct. Review UDC Article 6.4.3 and the example shown on the Residential Plot Plan Requirements found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Building-Safety/Plan-Examples/Plot-Plan-Example, and provide a correct lot coverage calculation.

7. The sheet index provided is not correct and should only reflect the sheets submitted.

The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code.

If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov.
08/27/2024 PDSD Application Completeness Express REVIEW COMPLETED