Permit Review Detail
Review Status: Requires Resubmit
Review Details: SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.1
Permit Number - TC-MDP-0625-00348
Review Name: SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/01/2025 | Residential Building | APPROVED | |||
| 06/24/2025 | ROW Engineering Review | APPROVED | A ROW permit shall be obtained prior to any work within the Public Right-of-Way. | ||
| 06/26/2025 | Fire New Construction | NOT REQUIRED | |||
| 07/15/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 07/15/2025 | Site Engineering | REQUIRES RESUBMIT | TC-MDP-0625-00348 525 W PRESIDENT ST Site engineering comments are as follows: Please clearly label the easement that runs on the west and south side of the property. Isaac Tineo - isaac.tineo@tucsonaz.gov |
||
| 07/08/2025 | Site Zoning | REQUIRES RESUBMIT | FROM: PDSD Zoning Review Section PROJECT: TC-MDP-0625-00348 525 W PRESIDENT ST – R-2 SFR w/ attached ADU (1st Review) TRANSMITTAL DATE: July 8, 2025 COMMENTS: Provide a detailed response letter with your submittal that clearly shows how you have addressed all Zoning comments. This site is located in the R-2 zone (UDC 4.7.9). A single-family residence (SFR) with an attached ADU is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.6, 8, & 9 and 6.6.3. 1. Provide a residential plot plan that meets the requirements found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Plan-Examples/Plot-Plan-Example, to include but not limited to: a. The plot plan shall be drawn at an engineering scale, i.e. 1” = 10’, 1” = 20’. Indicated the scale of the drawing on the plan. b. Provide the legal description “NATIONAL CITY NO 3 LOT 9 EXC S7.5' & W7.5' BLK 50” on the plot plan. c. Based on the legal description “NATIONAL CITY NO 3 LOT 9 EXC S7.5' & W7.5' BLK 50” the property dimensions are not correct. The north/south dimension should be 131.5’ and the east/west should be 51.96’. d. The lot square footage does not appear to be correct. Based on lot dimensions of 51.96’ x 131.5’ the lot square footage should be 6,832.7. e. Provide a dimension from centerline of Presidents St. to the face of curb and from the face of curb to the north property line. Based on Construction Plan I-754A sheet 2, found at: https://maps-and-records.tucsonaz.gov/construction-plans/details/I-754A, the distance from centerline to face of curb is 18’ and from curb to north property line is 12’. The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
||
| 06/24/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |