Permit Review Detail
Review Status: In Review
Review Details: SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.2
Permit Number - TC-MDP-0526-00338
Review Name: SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.2
Review Status: In Review
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| N/A | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| N/A | Fire New Construction | PENDING ASSIGNMENT | |||
| N/A | Residential Building | PENDING ASSIGNMENT | |||
| N/A | Residential Engineering | PENDING ASSIGNMENT | |||
| N/A | Residential Zoning | PENDING ASSIGNMENT | |||
| N/A | ROW Engineering Review | PENDING ASSIGNMENT | |||
| 05/21/2026 | Addressing Validation | REQUIRES RESUBMIT | 1) Please update the construction plans to remove the unit numbers. | ||
| 05/22/2026 | TW New Development Review Fast | REQUIRES RESUBMIT | Based on Tucson Water records, the parcel at 114 W Kelso St appears to be served by two existing 5/8-inch water meters, Meter No. 211048571 and Meter No. 231580191. Please provide the fixture unit count for each existing residence and for each proposed duplex unit. Also clarify which existing meter currently serves each existing residence, and identify which meter/service is proposed to serve the new duplex units. Based on Tucson Water meter sizing, a 5/8-inch water meter can accommodate a maximum of 20 fixture units. Tucson Water will review the total fixture unit count assigned to each meter to determine whether the existing meter sizes are adequate or if a meter upgrade will be required. |
||
| 05/21/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |