| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/19/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 09/15/2025 | Residential Building | REQUIRES RESUBMIT | The last residential review asked for the finished floor elevation, the response letter claimed it was provided. The FFE is not present on your plans. Please provide the FFE and re submit. | ||
| 09/09/2025 | ROW Engineering Review | REQUIRES RESUBMIT | DTM Comments - Site plan needs to call out and show existing and future right of way feature for Sidewalk and Driveway as was call out on TC-MDP-0525-00317. | ||
| 09/15/2025 | Site Engineering | REQUIRES RESUBMIT | TC-MDP-0525-00316 456 W WYOMING ST Site engineering comments are as follows: Site Engineering cannot approve this permit application until the other reviewers’ requirements/comments are satisfied. Ryan Insalaco Engineering Associate ryan.insalaco@tucsonaz.gov |
||
| 09/19/2025 | Site Zoning | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Ramiro Olivarez PDSD Zoning Review PROJECT: TC-MDP-0525-00316 456 W WYOMING ST| R-2 Zone New Single-Family Residence (2nd Review) TRANSMITTAL DATE: 09/19/2025 This site is located in the R-2 zone (UDC 4.7.9). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.6, .9, & .10. 1. Comment: The site plan should be designed to include the information as noted on the sample plot plan. See the link below for the information that is required on the plot plan. https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/residential_plot_plan_requirements.pdf . 2. Comment: Notate the Legal description. 3. Comment: Per UDC article 6.4.3, lot coverage shall include the area of a lot covered by buildings, storage areas, including dimensioned vehicular use areas. Per UDC Article 6.4.3.C.1.a Roofed areas, Porches, open on at least one side, are not included in the total lot coverage calculation/percentage. Remove the porch square footage from the final/total lot coverage calculation and percentage. 4. Comment: Label on the site plan the zone (R-2) and all the adjacent property zones (R-2). Or show a zoning detail of this properties zone and all adjacent property zones. (As noted on the sample plot plan above) 5. Comment: Draw, label, and dimension the centerline of Wyoming St to the back-of-curb and from the back-of-curb to the property line. 6. Comment: Draw, label, and dimension the future Right-of-Way. Dimension the 20’ front street perimeter yard from the future Right-of-Way. 7. Comment: Dimension the width of the driveway. 8. Comment: Draw, label, and dimension the 5’ utility easement. 9. Comment: Dimension setbacks from the water heater enclosure to the property line. 10. Comment: Additional comments may be forthcoming on the next review based on the proposed use for the addition and applicable use specific standards. If you have any questions about this transmittal, please contact Ramiro Olivarez at Ramiro.Olivarez@tucsonaz.gov |
||
| 08/29/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |