| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/10/2025 | Fire New Construction | NOT REQUIRED | |||
| 06/18/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 06/12/2025 | Residential Building | REQUIRES RESUBMIT | ACTIVITY NO. TC-MDP-0525-00316 ADDRESS/PARCEL: (456 W WYOMING ST TUCSON, AZ 85706) Submit your revised drawings along with a detailed response letter, which states how all Building Review Section comments were addressed. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review. Review will not proceed without the response letter. COMMENTS: 1. Please show the FFE, finished floor elevation, and the RIM elevation of the nearest upstream manhole on the site plan. a. Will be used to confirm whether a backwater valve is required 2. Please resubmit |
||
| 06/04/2025 | ROW Engineering Review | REQUIRES RESUBMIT | Review Notes: 1) Property expansion exceeding 25% Requires Civil Improvement of Sidewalk, Driveway, and Curb Line. 2) Driveway (PAG SD 206) Max. width for residential driveway is 20’. Show & Call out on location and dimensions on Site plan. 3)Sidewalk (PAG SD 200) 5’ for Local roadways - Show & Call out on Site Plan and show dimensions' 4) Unused existing curb cuts shall be closed. 5) Site plan: Show existing and proposed Right-of-Way features. Provide distances and dimensions 6) Show all proposed Utility connection and main locations on Design plans |
||
| 06/13/2025 | Site Engineering | REQUIRES RESUBMIT | TC-MDP-0525-00316 456 W WYOMING ST Site engineering comments are as follows: Please show on the plans the information required by Residential Building and ROW Engineering Review. Site engineering cannot approve until this information is provided. Isaac Tineo isaac.tineo@tucsonaz.gov |
||
| 06/18/2025 | Site Zoning | REQUIRES RESUBMIT | FROM: Olga Salazar PDSD Zoning Review Section PROJECT: TC-MDP-0525-00316 Residential SFR (1st Review) 456 W WYOMING ST TUCSON, AZ 85706 R-2 TRANSMITTAL DATE: 06/18/2025 DUE DATE: 06/16/2025 COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. 01. COMMENT: The submitted plan does not meet the minimum plot plan requirements for review. Refer to the sample plot plan document for information that should be on the submitted plan. Add the following information as depicted or noted on the sample plot plan sheet. Use the following URL to see or download the sample residential drawings. https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Plan-Examples/Floor-Plan-Example a. Legal description b. Owner’s information c. Project description d. Adjacent zoning of all four sides, including across the street. e. Section, township and range f. Dimension driveway g. Dimension setbacks from the water heater enclosure to the property line. h. Dimensioned elevation drawing, dimensioned walls from design grade to top of walls, gavel end, in order to verify setbacks meet code requirements. i. Label street information j. Dimension the street center line to property line k. Dimension curb to property line l. Dimension the pavement half width 02. COMMENT: Additional comments may be forthcoming based on corrections to the plot plan and responses to zoning review comments. If you have any questions about this transmittal, please contact Zone1.Desk@tucsonaz.gov RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Corrected plan set and comment response letter. To resubmit visit Tucson Development Center at https://tdc-online.tucsonaz.gov/#/home. |
||
| 06/02/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |