Permit Review Detail
Review Status: Requires Resubmit
Review Details: SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.1
Permit Number - TC-MDP-0525-00311
Review Name: SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/04/2025 | PDSD Application Completeness Express | APPROVED | |||
| 09/18/2025 | Residential Building | APPROVED | |||
| 09/09/2025 | Fire New Construction | NOT REQUIRED | |||
| 09/23/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 09/19/2025 | ROW Engineering Review | REQUIRES RESUBMIT | Show existing ROW features Sidewalk required along street frontage. New sidewalk per PAG SD 200 New driveway per PAG SD 206 DTM Comment file and driveway layout have been added to attachments. |
||
| 09/15/2025 | Site Engineering | REQUIRES RESUBMIT | Permit: TC-MDP-0525-00311 Location: 2975 N WALNUT AV Review Date: 9/15/2025 Site Engineering Comments: 1. This property resides within an X-Shaded 100_year-Floodplain and will require a floodplain use permit with elevation certificate. 2. The sub-records of the building permit have been opened for FPU submission. 3. For the proposed SFR with ADU, it will be required to be elevated 1ft above the base flood elevation. Due to the X-Shaded zone, the base flood elevation is based on 12inches above natural grade. 4. For resubmission of the residential permit and the first submission of the floodplain use permit, ensure to denote the required finished floor elevation onto the construction plans. If you have any questions or concerns, please contact Marco Contreras Marco.contreras@tucsonaz.gov |
||
| 09/23/2025 | Site Zoning | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Bobby Parsons Zoning Section Review PROJECT: TC-MDP-0525-00311 2975 N. Walnut Ave. Tucson, AZ 85712 Duplex SFR & ADU (1st Review) TRANSMITTAL DATE: 9/23/2025 This site is located in the MH-1 zone (UDC 4.7.10). A single-family residence is a permitted use in this zone (Table 4.8-2). 1. Comment: Please draw, label, and dimension the ½ Right of Way from the centerline to the face of curb and from the face of curb to the property line along N. Walnut Avenue. Refer to Paving Improvement Plan I-73-042 pg. 5 if necessary. https://maps-and-records.tucsonaz.gov/construction-plans/details/I-73-042 2. Comment: Please dimension the property lines. 3. Comment: Please include the surrounding zoning classification as noted on the sample site plan. https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/residential_plot_plan_requirements_dtm-comments.pdf 4. Comment: Additional comments may be forthcoming depending on responses to zoning review comments and updated plans submitted. If you have any questions about this transmittal, please contact Bobby Parsons at Robert.Parsons@tucsonaz.gov. |