Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-MDP-0525-00310
Parcel: 129134220

Address:
913 E 36TH ST

Review Status: Requires Resubmit

Review Details: SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.1

Permit Number - TC-MDP-0525-00310
Review Name: SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
09/19/2025 Residential Building APPROVED
09/09/2025 Fire New Construction NOT REQUIRED
09/19/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
09/19/2025 ROW Engineering Review REQUIRES RESUBMIT Sidewalk and driveway are not required. COT Prop 407 plans on constructing a shared driveway and sidewalk along 36th st.
Shared access easement required for future driveway. Show on plans
Show existing utility poles in ROW to determine future driveway location. Should be 5' from utility pole. One pole is a "topped" pole and should be on TEP's schedule to remove.
09/15/2025 Site Engineering REQUIRES RESUBMIT Permit: TC-MDP-0525-00310
Location: 913 E 36TH ST
Review Date: 9/15/2025
Site Engineering Comments:
1. This property resides within the City of Tucson Downtown Airport-colonia Progreso Wash Floodplain and will require a floodplain use permit with elevation certificate.
2. The sub-records of the building permit have been opened for FPU submission.
3. For the proposed SFR with ADU, the estimated base flood elevation was determined to be at 2454.68, therefore the required Finished floor elevation will be 2455.68 FT NAV88
4. For resubmission of the residential permit and the first submission of the floodplain use permit, ensure to denote this require finished floor elevation onto the construction plans.


If you have any questions or concerns, please contact
Marco Contreras
Marco.contreras@tucsonaz.gov
09/19/2025 Site Zoning REQUIRES RESUBMIT PDSD TRANSMITTAL

FROM: Jeffrey W. Cassidy, Planner
Planning & Development Services Department – Current Zoning Review Section

PROJECT: TC-MDP-052500310 – Residential Building – SFR / ADU Model
913 E 36th St Tucson, AZ 85713 (C-2 Zoning)
Site Plan Review – 1st Review

TRANSMITTAL DATE: September 19, 2025

This site is in the C-2 Residence Zone (UDC 4.7.21). A single-family residence and accessory dwelling unit are permitted uses in this zone (Table 4.8-4) subject to Use Specific Standards 6.6.3.

Plan review for the above referenced single-family residence has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment updates; revisions are processed if changes occur after the permit is issued.

SCOPE OF REVIEW:
The scope of this plan review covers zoning, use(s), legal description, adjacent properties, setbacks (building or wall heights), dimensional standards, property permitting history, density (units/lot size), and lot calculation (enclosed building and structure, parking, and driveway versus overall lot size) requirements. All code references are to the Tucson, AZ Unified Development Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval.

SITE PLAN:

1. COMMENT: The site plan sheet provided is incomplete.

a) Provide a site plan that meets the requirements show in the plot plan example at the following link:

https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Plan-Examples/Plot-Plan-Example

More specifically:

1) Provide missing legal description (per county website): GRAND VIEW LOT 11 EXC 36TH ST BLK 31

2) Label 36th Street and acknowledge whether it is private or public and provide recordation data.


3) Provide missing dimension from centerline of 36th street to curb.

4) Provide missing dimension from curb to property line.

5) Draw and dimension two parking spaces in parking area.

6) Provide missing zoning labels on all four sides of this parcel including this parcel.

7) Provide missing property line labels.

8) Provide missing Section, Township and Range on the Vicinity Map, label the vicinity map, provide a north arrow and label the streets with the sheet font so it is more legible.

9) Provide missing site plan scale and corresponding graphic scale.

10) Provide missing subdivision name: Subdivision Plat Map for Book 2, Page 39
GRAND VIEW ADDITION

2. COMMENT: Per 6.6.3.C., “detached accessory buildings, including accessory dwelling units, are not permitted in the buildable area extending the full width of the lot between the principal building and the front street lot line, except for shade structures not over 400 square feet in floor area, terraces and steps not over three fee high above the natural grade, paved areas and fences or walls.” As currently the shown the ADU and Single-Family Residence would need to swap locations (rotate floor plan?).

3. COMMENT: Zoning acknowledges permits have been submitted for the parcel 129134230 to the east of this parcel. To avoid having to submit for and meet Development Package requirements, demonstrate how parcel 129134220 will be physically separated from parcel 129134230 whether it be through a wall, fence, etcetera. Draw, dimension and label the separation type, material and height.

4. COMMENT: Additional comments may be forthcoming on the next review based on responses to Zoning and other the PDSD reviewer comments.

RESUBMITTAL OF THE FOLLOWING IS REQUIRED:
1. Corrected site plan.
2. Provide a detailed response letter with your submittal that clearly shows how you have addressed all Zoning comments.

To resubmit visit Tucson Development Center at https://tdc-online.tucsonaz.gov/#/home

Instructions for resubmittal - https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/tdc-faq/old-pdfs/double-old/resubmittals.pdf

If you have any questions about this transmittal, please contact jeffrey.cassidy@tucsonaz.gov

The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code .
09/05/2025 PDSD Application Completeness Express REVIEW COMPLETED