Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-MDP-0524-00597
Parcel: 14025046B

Address:
1124 E MILTON RD

Review Status: Requires Resubmit

Review Details: SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.1

Permit Number - TC-MDP-0524-00597
Review Name: SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
05/24/2024 Site Engineering APPROVED
05/22/2024 Site Zoning APPROVED
05/10/2024 Fire New Construction NOT REQUIRED
05/28/2024 Bldg Permits - Post Review Express PENDING ASSIGNMENT
05/21/2024 Residential Building REQUIRES RESUBMIT Permit Review TC-MDP-0524-00597 (1124 E MILTON RD TUCSON, AZ 85706)
Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received.
Code reference, 2018 International Residential Code (IRC), 2017.


1. Provide elevation measurements for Next Upstream Manhole cover and Finished Floor Elevation. Provide Backwater valve protection as required.
Backwater valve protection:
https://www.tucsonaz.gov/files/sharedassets/public/pdsd/documents/building-code/2018_-_irc_amendments.pdf Section P3008.1 Where required. Where the finish floor elevation is less than 12 inches above the elevation of the next upstream manhole cover in the sewer, a backwater valve shall be installed in the building drain or branch of the building drain serving that floor.

2. Where it is necessary to protect a cleanout plug from the loads of vehicular traffic, cleanout assemblies in accordance with ASME A112.36.2M Shall be installed, P3005.2.10.2. >>> Key note ā€˜P’ shows a cleanout that may be in an area subject to vehicular traffic.



Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov
05/10/2024 PDSD Application Completeness Express REVIEW COMPLETED
05/28/2024 ROW Engineering Review REVIEW COMPLETED