Permit Review Detail
Review Status: In Review
Review Details: SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.1
Permit Number - TC-MDP-0426-00262
Review Name: SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.1
Review Status: In Review
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| N/A | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| N/A | Fire New Construction | PENDING ASSIGNMENT | |||
| N/A | Residential Building | PENDING ASSIGNMENT | |||
| N/A | Residential Zoning | PENDING ASSIGNMENT | |||
| N/A | ROW Engineering Review | PENDING ASSIGNMENT | |||
| N/A | TW New Development Review Fast | PENDING ASSIGNMENT | |||
| 04/29/2026 | Residential Engineering | REQUIRES RESUBMIT | Permit Activity Number: TC-MDP-0426-00262 (1st Review) Project: New 2 story duplex model plan Location: 1752 W VALDEZ CT Review Date: 4/28/2026 Reviewer: Marco Contreras – Engineering Associate - Site Engineering Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter review time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment updates; revisions are processed if changes occur after the permit is issued. Provide a response letter addressing each comment with location of change on the plans. Submit the separate response letter and plan set files. Site Engineering Review Comments: 1. It will be required that the utilities shown to be moved/placed outside of the erosion hazard setback area associated with Hideout Wash. 2. Denote the FFE and FG as established by the associated tentative plat. 3. Provide an acceptable scale to the plan set. 4. As the proposed development is a new dwelling (ADU, SFR, Duplex, Etc), Per the City of Tucson Inclusive Home Design Ordinance: https://www.tucsonaz.gov/files/sharedassets/public/v/1/city-services/planning-development-services/documents/inclusivehomedesignordinance.pdf, all new dwellings and units have a requirement to provide an “accessible route from public and common areas, including, but not limited to, a driveway or public street or sidewalk”. Draw, dimension, and label an accessible route from the driveway, sidewalk, or street to an accessible entrance. a. Refer to Technical Standards Manual Section 7-01.4.3 for sidewalk/pathway specifications including the minimum 4ft-width and composition minimums. b. Action Items: Provide a width call-out, proposed slope, and label the walkway as the “Accessible Route” leading to the new home entrance If you have any questions or concerns, please contact Marco Contreras at Marco.contreras@tucsonaz.gov |
||
| 04/28/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |