Permit: TC-MDP-0426-00262
Permit Details
Status:
Inspections
Type:
Model Building Permit
Address:
1752 W VALDEZ CT UNIT 1
Address NEW:
1752 W VALDEZ CT UNIT 1
Apply Date:
04/24/2026
Applicant:
Brisa Soto
Description:
New 2 story duplex model plan. (MASTER MODEL PLAN TC-MDP-0525-00285) ; REV_1
Permit Reviews
Permit Number - TC-MDP-0426-00262
Permit Status: Inspections
Permit Description: New 2 story duplex model plan. (MASTER MODEL PLAN TC-MDP-0525-00285) ; REV_1
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 05/22/2026 | SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.2 | 06/05/2026 | APPROVED |
| 07/23/2026 | ADMINISTRATIVE v.1 | 07/23/2026 | REQUIRES RESUBMIT |
| 04/28/2026 | SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.1 | 05/07/2026 | REQUIRES RESUBMIT |
Outstanding Activity Conditions
Permit Number - TC-MDP-0426-00262
Permit Status: Inspections
Permit Description: New 2 story duplex model plan. (MASTER MODEL PLAN TC-MDP-0525-00285) ; REV_1
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 04/23/2026 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. |
Conditions
Permit Number - TC-MDP-0426-00262
Permit Status: Inspections
Permit Description: New 2 story duplex model plan. (MASTER MODEL PLAN TC-MDP-0525-00285) ; REV_1
| Date | Description | Comments |
|---|---|---|
| 06/05/2026 | Property is a duplex. Please contact Pima County Addressing to resolve issue. Addressing@pima.gov or 520-724-9512 | |
| 04/28/2026 | Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit is required prior to issuance of permit. The Affidavit form is available at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit. | |
| 07/23/2026 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. For review and assessment: apply online at https://permits.pima.gov/ or contact us at sewer@pima.gov, (520) 724-9900. |
Outstanding Inspections
Permit Status: Inspections
Permit Number: TC-MDP-0426-00262
Permite Description: New 2 story duplex model plan. (MASTER MODEL PLAN TC-MDP-0525-00285) ; REV_1
Total Outstanding Inspections - 1
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/25/2026 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | N/A | Re-inspection required | 9-25-26 strap flex duct at 4 feet from opening and at 4 foot intervals at marked locations and throughout, some locations was not marked, but ensure that all duct is strapped correctly.*. Add BANG plates to marked locations and throughout, some locations was not marked, but ensure that bang plates are added were needed, when hole through wood is less than one and a quarter inch away from face of stud bang plate is required. *fire blocking required at all dead spaces where duct runs through top and bottom. * STOPPED INSPECTION AT THIS TIME. MORE ITEMS MAY BE ADDED REINSPECT IS REQUIRED PLEASE RE-WALK . |
Completed Inspections
Permit Status: Inspections
Permit Number: TC-MDP-0426-00262
Permit Description: New 2 story duplex model plan. (MASTER MODEL PLAN TC-MDP-0525-00285) ; REV_1
Total Completed Inspections - 5
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/10/2026 | COT - RSPL - Rough Soil | Passed | 8-10-26: rough soil-underground plumbing only verified per plans & under test. Okay to backfill using shading materials. | |
| 08/17/2026 | COT - RSBU - Excavation/Rebar/Zoning | Passed | ||
| 08/17/2026 | COT - RSBU - Preslab | Passed | ||
| 09/11/2026 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | 9/11/26: exterior clips/sheathing approved. | |
| 09/11/2026 | COT - RSBU - Roof Nailing | Passed | 9/11/26: okay to dry-in roof. |