Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: TC-MDP-0226-00061
Parcel: 120073870

Review Status: In Review

Review Details: SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.1

Permit Number - TC-MDP-0226-00061
Review Name: SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.1
Review Status: In Review
Review Date Reviewer's Name Type of Review Description Status Comments
02/12/2026 Fire New Construction NOT REQUIRED
N/A Bldg Permits - Post Review Express PENDING ASSIGNMENT
N/A Residential Building PENDING ASSIGNMENT
N/A Residential Engineering PENDING ASSIGNMENT
N/A TW New Development Review Fast PENDING ASSIGNMENT
02/13/2026 Residential Zoning REQUIRES RESUBMIT PDSD TRANSMITTAL

FROM: Erick Bieber
Planning & Development Services Department – Zoning Review Section

PROJECT: TC-MDP-0226-00061
408 W Columbia St, Tucson, AZ 85714
Model Building Permit (1st Review)

TRANSMITTAL DATE: February 13th, 2026

This site is located in the R-2 zone (UDC 4.7.9). A single-family residence is a permitted use in this zone subject to use-specific standards 4.9.7.B.6, .9 and .10.

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Correct plans, as noted in the comments below, along with a response letter indicating how all Site Zoning comments were addressed.

1. (Comment) Per Ordinance 12219, the Middle Housing Code Amendment requires basic drought resistant landscaping to be indicated on the site plan for 1–4-unit residential projects submitted starting in 2026. The requirements include but are not limited to:
a. One canopy tree required for every 1,000sqft of gross floor area of the development project (0-1,000sqft – 1 tree, 1,001-2,000sqft – 2 trees). The current proposal shows only one tree.
b. 5 feet of vegetative groundcover for the length of the street frontage, minus the curb cut width. For this lot, approximately 195sqft of vegetative groundcover will be required in the front street setback. Show this area on the site plan.
c. These requirements may be met by existing landscape features on the site, but that existing landscaping must be indicated on the site plan.
d. See Ordinance 12219 for the full list of landscaping standards.

The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code

For questions regarding Zoning comments, please contact me at: Erick.Bieber@tucsonaz.gov
02/12/2026 PDSD Application Completeness Express REVIEW COMPLETED
02/17/2026 ROW Engineering Review REVIEW COMPLETED DTM Comments - All DTM Issues have been Noted-
All work within ROW will require separate and individual ROW permits per scope of work
Driveway to meet PAG 206 Standard Details and Sidewalk to Meet PAG 200 Standard detial.