Permit Review Detail
Review Status: Requires Resubmit
Review Details: SITE FROM MODEL PERMIT - SUBDIVISION REVISION v.1
Permit Number - TC-MDP-0125-00051
Review Name: SITE FROM MODEL PERMIT - SUBDIVISION REVISION v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 02/18/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 02/07/2025 | Light Residential Building Review (OIP) Fast | REQUIRES RESUBMIT | Permit Review Commercial Electrical: TC-MDP-0125-00051 (7410 S BULLSEYE WY TUCSON, AZ 85756) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2018 International Building Code (IBC), 2017 National Electrical Code (NEC). 1. Show meeting room receptacles spaced per NEC 210.65 Meeting Rooms. Reference also NEC 210.65(B) and 210.52(A)(1) through (A)(4). “Receptacles shall be installed such that no point measured horizontally along the floor line of any wall space is more than 1.8 m (6 ft) from a receptacle outlet.” Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov |
||
| 02/07/2025 | Residential Building Fast | REQUIRES RESUBMIT | SALES OFFICE - Review as commercial permit because of the change in use of the structure. ACTIVITY NO. TC-MDP-0125-00051 ADDRESS/PARCEL: (7410 S BULLSEYE WY TUCSON, AZ 85756) COMMENTS: 1. Please submit the Manual J, D, S and The Extended Rating Table info for the Sales Office space. 2. Please resubmit. |
||
| 02/18/2025 | Site Engineering Fast | REQUIRES RESUBMIT | TC-MDP-0125-00051 7410 S BULLSEYE WY Site Engineering comments are as follows: 1. Please add a general note stating that a demo permit will be required for the conversion of the parking lot back to a residential lot. 2. Please add a general note that elevations and compaction will be required prior to the issuance of a building permit on lot 292. 3. Any basin remediation construction required after converting Lot 292 back into a residential lot will need to be completed prior to the issuance of a residential building permit. Ryan Insalaco – ryan.insalaco@tucsonaz.gov |
||
| 02/17/2025 | Site Zoning Fast | REQUIRES RESUBMIT | FROM: PDSD Zoning Review PROJECT: TC-MDP-0125-00051 7410 S BULLSEYE WY. – R-1 (FLD) Sales Office (1st Review) TRANSMITTAL DATE: February 17, 2025 Resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This site is located in the R-1 zone (UDC 4.7.8). A single-family residential subdivision is a permitted use in this zone (Table 4.8-2), See UDC Article 8.7.3. 1. The mounting height for the accessible sign is not correct and should be 7’-0” to the bottom of the lowest sign. 2. The wheel stop location dimension is not correct. Review UDC Article 7.4.6.H.3 and Figure 7.4.6-C and provide the correct dimension. 3. The location of the proposed accessible parking sign appears to encroach into the 2’-6” vehicle overhang area. 4. The 20.4’ PAAL shown behind the accessible parking space does not meet the minimum required, 24’ for access to 90 degree parking, UDC Tables 7.4.6-1 & 7.4.6-2. The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov |
||
| 02/07/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |